INFORMATION OF CIRCULATION FROM SOFT-TISSUE AND DENTAL-PULP BY MEANS OF PULSATILE REFLECTED LIGHT - FURTHER DEVELOPMENT OF OPTICAL PULP VITALOMETRY
Autore:
OIKARINEN KS; KAINULAINEN V; SARKELA V; ALANISKA K; KOPOLA H;
Indirizzi:
UNIV OULU,INST DENT,DEPT ORAL & MAXILLOFACIAL SURG,AAPISTIE 3 SF-90220 OULU FINLAND OULU UNIV HOSP,INST DENT,DEPT ORAL & MAXILLOFACIAL SURG OULU FINLAND OULU UNIV HOSP,ORAL & MAXILLOFACIAL UNIT OULU FINLAND UNIV OULU,TECH FAC,DEPT ELECT ENGN OULU FINLAND VTT ELECT OULU FINLAND
Titolo Testata:
Oral surgery, oral medicine, oral pathology, oral radiology and endodontics
fascicolo: 3, volume: 84, anno: 1997,
pagine: 315 - 320
SICI:
1079-2104(1997)84:3<315:IOCFSA>2.0.ZU;2-A
Fonte:
ISI
Lingua:
ENG
Soggetto:
LASER-DOPPLER FLOWMETRY; VITALITY; BLOOD; TEETH;
Tipo documento:
Article
Natura:
Periodico
Citazioni:
15
Recensione:
Indirizzi per estratti:
Citazione:
K.S. Oikarinen et al., "INFORMATION OF CIRCULATION FROM SOFT-TISSUE AND DENTAL-PULP BY MEANS OF PULSATILE REFLECTED LIGHT - FURTHER DEVELOPMENT OF OPTICAL PULP VITALOMETRY", Oral surgery, oral medicine, oral pathology, oral radiology and endodontics, 84(3), 1997, pp. 315-320

Abstract

Objectives. To show experimentally and clinically that information ofblood circulation patterns can be obtained through dentin and enamel by means of reflected light. Study design. Several different experimental techniques were developed in vitro leading up to in vivo tests. Results. Pulsatile information of back-scattered light al 560 nm was obtained in an experiment in which a thread with white and red sections was pulled through the empty pulp cavum. The pulsatile information of back-scattered light of 560 nm wavelength was detected from a forefinger of a volunteer through dental hard tissue plates. There was a difference in the radiant flux of back-scattered light in extracted teeth filled with various materials. Photoplethysmograms obtained from the vital pulp of a 24-year-old woman were analyzed with Fast Fourier Transformation (FFT). The analyzed data showed a dominant amplitude of heart rate near 1 Hz. Conclusions. Tests indicated that reliable informationof circulation can be obtained from the dental pulp chamber by means of the optical reflection method. This could serve as a model for a new type of pulp vitalometer.