Catalogo Articoli (Spogli Riviste)

OPAC HELP

Titolo:
A charged-particle detector based on proportional tubes with a segmented cathode and cathode readout
Autore:
Blick, AM; Bogolyubsky, MY; Erin, SV; Lobanov, MO; Minaev, NG; Sadovsky, SA; Samoilenko, VD; Suzdalev, VI; Tikhonov, VV; Kharlov, YV; Di Mauro, A; Martinengo, P; Piuz, F; Van Beelen, J; Williams, D; Ippolitov, MS; Sibiryak, YG; Volkov, MA; Klovning, A; Maeland, OA; Odland, OH; Rongved, R; Skaali, B;
Indirizzi:
State Res Ctr Russia, Inst High Energy Phys, Protvino 142281, Moscow Oblast, Russia State Res Ctr Russia Protvino Moscow Oblast Russia 142281 Oblast, Russia CERN, Geneva, Switzerland CERN Geneva SwitzerlandCERN, Geneva, Switzerland IV Kurchatov Atom Energy Inst, Russian Res Ctr, Moscow 123182, Russia IV Kurchatov Atom Energy Inst Moscow Russia 123182 Moscow 123182, Russia Univ Bergen, Dept Phys, N-5020 Bergen, Norway Univ Bergen Bergen Norway N-5020 ergen, Dept Phys, N-5020 Bergen, Norway Univ Oslo, Dept Phys, N-0316 Oslo, Norway Univ Oslo Oslo Norway N-0316Univ Oslo, Dept Phys, N-0316 Oslo, Norway
Titolo Testata:
INSTRUMENTS AND EXPERIMENTAL TECHNIQUES
fascicolo: 3, volume: 44, anno: 2001,
pagine: 339 - 346
SICI:
0020-4412(200105/06)44:3<339:ACDBOP>2.0.ZU;2-0
Fonte:
ISI
Lingua:
ENG
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Engineering, Computing & Technology
Citazioni:
16
Recensione:
Indirizzi per estratti:
Indirizzo: Blick, AM State Res Ctr Russia, Inst High Energy Phys, Ul Pobedy 1, Protvino 142281,Moscow Oblast, Russia State Res Ctr Russia Ul Pobedy 1 Protvino Moscow Oblast Russia 142281
Citazione:
A.M. Blick et al., "A charged-particle detector based on proportional tubes with a segmented cathode and cathode readout", INSTR EXP R, 44(3), 2001, pp. 339-346

Abstract

A charged-particle detector based on proportional tubes with cathode readout is described. The cathode is sectionalized into 2.2 x 2.2-cm pads. The detector was tested on high-energy particle beams. At an anode-to-cathode distance of 1.1 cm, the spatial resolution was 1.25 mm along the anode wire. A simulation model of the detector on the basis of the measured pad-response function was proposed, compared to the experimental data, and used to calculate the two-track resolution. The detector can be used in various experiments as a large-area multiparticle two-coordinate detector.

ASDD Area Sistemi Dipartimentali e Documentali, Università di Bologna, Catalogo delle riviste ed altri periodici
Documento generato il 28/11/20 alle ore 09:07:20