Accuracy of in vivo carotid B-mode ultrasound compared with pathological analysis - Intima-media thickening, lumen diameter, and cross-sectional area
Autore:
Schulte-Altedorneburg, G; Droste, DW; Felszeghy, S; Kellermann, M; Popa, V; Hegedus, K; Hegedus, C; Schmid, M; Modis, L; Ringelstein, EB; Csiba, L;
Indirizzi:
Debrecen Univ Med, Med & Hlth Sci Ctr, Fac Med, Dept Neurol, H-4012 Debrecen, Hungary Debrecen Univ Med Debrecen Hungary H-4012 urol, H-4012 Debrecen, Hungary Debrecen Univ Med, Med & Hlth Sci Ctr, Fac Med, Dept Anat Histol & Embryol, H-4012 Debrecen, Hungary Debrecen Univ Med Debrecen Hungary H-4012 ryol, H-4012 Debrecen, Hungary Debrecen Univ Med, Med & Hlth Sci Ctr, Fac Med, Dept Psychiat, H-4012 Debrecen, Hungary Debrecen Univ Med Debrecen Hungary H-4012 hiat, H-4012 Debrecen, Hungary Debrecen Univ Med, Med & Hlth Sci Ctr, Fac Med, Dept Stomatol, H-4012 Debrecen, Hungary Debrecen Univ Med Debrecen Hungary H-4012 atol, H-4012 Debrecen, Hungary Univ Munster, Dept Neurol, D-4400 Munster, Germany Univ Munster Munster Germany D-4400 Dept Neurol, D-4400 Munster, Germany Univ Munich, Inst Med Informat Biometry & Epidemiol, Munich, Germany Univ Munich Munich Germany format Biometry & Epidemiol, Munich, Germany
Titolo Testata:
STROKE
fascicolo: 7, volume: 32, anno: 2001,
pagine: 1520 - 1524
SICI:
0039-2499(200107)32:7<1520:AOIVCB>2.0.ZU;2-W
Fonte:
ISI
Lingua:
ENG
Soggetto:
ARTERY INTIMA; THICKNESS; WALL; INFARCTION; PATTERNS; ADULTS; FLOW;
Keywords:
carotid arteries; pathology; ultrasonography;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Life Sciences
Citazioni:
18
Recensione:
Indirizzi per estratti:
Indirizzo: Schulte-Altedorneburg, G Klinikum Augsburg, Dept Radiol, Stenglinstr 2, D-86156 Augsburg, Germany Klinikum Augsburg Stenglinstr 2 Augsburg Germany D-86156
Citazione:
G. Schulte-Altedorneburg et al., "Accuracy of in vivo carotid B-mode ultrasound compared with pathological analysis - Intima-media thickening, lumen diameter, and cross-sectional area", STROKE, 32(7), 2001, pp. 1520-1524

Abstract

Background and Purpose-This study aimed to determine the correlation of invivo ultrasound measurements of intima-media thickening (IMT), lumen diameter, and cross-sectional area of the common carotid artery (CCA) with corresponding measurements obtained by gross pathology and histology,Methods-Sixty-six moribund neurological patients (mean age 71 years) underwent B-mode ultrasound of the CCA a few days before death. During autopsy, carotid specimens were removed in tote. Carotid arteries were ligated:and cannulated for injection of a hydrophilic embedding material under standardized conditions. The carotid bifurcation was frozen and cut manually in 3-mmcross slices. Digital image analysis was carried out to determine the diameter and the cross-sectional area of the frozen slices of the CCA. IMT was assessed by light microscope. Ultrasonic and planimetric data were compared. Results-Mean measurements of lumen diameter and cross-sectional area were 7.13 +/-1.27 mm and 0.496 +/-0.167 cm(2), respectively, by ultrasound, and 7.81 +/-1.45 mm and 0.516 +/-0.194 cm(2), respectively, by planimetric analysis of the unfixed redistended carotid arteries (R-2=0.389 and 0.497). Themean IMT was 1.005 +/-0.267 mm by ultrasound and 0.67 +/-0.141 mm histologically, resulting in a mean difference of -31%. Conclusions-Transcutaneous B-mode ultrasound provides a reliable approach for in vivo measurements of the cross-sectional area and, less exactly, of the lumen diameter of the CCA. Compared with histological results, in vivo ultrasound measurements of the IMT are systematically larger.