Evaluation of the overall efficacy of the Omron office digital blood pressure HEM-907 monitor in adults
Autore:
White, WB; Anwar, YA;
Indirizzi:
Univ Connecticut, Ctr Hlth, Sect Hypertens & Clin Pharmacol, Farmington, CT 06030 USA Univ Connecticut Farmington CT USA 06030 rmacol, Farmington, CT 06030 USA
Titolo Testata:
BLOOD PRESSURE MONITORING
fascicolo: 2, volume: 6, anno: 2001,
pagine: 107 - 110
SICI:
1359-5237(200104)6:2<107:EOTOEO>2.0.ZU;2-Z
Fonte:
ISI
Lingua:
ENG
Keywords:
non-invasive blood pressure; Association for the Advancement of Medical Instrumentation (AAMI) validation;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Citazioni:
9
Recensione:
Indirizzi per estratti:
Indirizzo: White, WB Univ Connecticut, Ctr Hlth, Sect Hypertens & Clin Pharmacol, 263Farmington Ave, Farmington, CT 06030 USA Univ Connecticut 263 Farmington Ave Farmington CT USA 06030 USA
Citazione:
W.B. White e Y.A. Anwar, "Evaluation of the overall efficacy of the Omron office digital blood pressure HEM-907 monitor in adults", BL PRESS M, 6(2), 2001, pp. 107-110

Abstract

Background Non-invasive self blood pressure monitoring has become increasingly popular. To assure the accuracy of devices used for this purpose, all need to be validated independently prior to marketing. The objective of this study was to assess the accuracy of the HEM-907, a new semi-automatic, non-invasive, osciliometric blood pressure monitoring device specifically designed to be used in the clinic or physician's office setting. Methods Blood pressure measurements taken employing this device were compared with the results obtained by two experienced observers using a mercury sphygmomanometer on 100 subjects and patients (384 measurements). The limits of agreement were calculated for the device compared with the results of the two observers according to the standards of the Association for the Advancement of Medical instrumentation (AAMI). Results The agreement between the two observers was -0.36 +/- 2.32 mmHg for systolic blood pressure and 0.02 +/- 2.42 mmHg for diastolic blood pressure. The agreement between the device and the observers was 1.56 +/- 4.42 mmHg and 3.49 +/- 4.61 mmHg for systolic and diastolic blood pressure respectively. Conclusions The Omron HEM-907 satisfied the AAMI criteria for accuracy fora non-invasive blood pressure monitoring device. Blood Press Monit 6:107-110 (C) 2001 Lippincott Williams & Wilkins.