Intraocular lens designed for the newborn infant eye
Autore:
Lundvall, A; Kugelberg, U; vander Mooren, M; vander Mooren, M; Zetterstrom, C;
Indirizzi:
St Eriks Eye Hosp, Karolinska Inst, SE-11282 Stockholm, Sweden St Eriks Eye Hosp Stockholm Sweden SE-11282 , SE-11282 Stockholm, Sweden Pharmacia & Upjohn Inc, Dept Preclin Ophthalmol, Uppsala, Sweden Pharmacia& Upjohn Inc Uppsala Sweden eclin Ophthalmol, Uppsala, Sweden Pharmacia & Upjohn Inc, Groningen, Netherlands Pharmacia & Upjohn Inc Groningen Netherlands nc, Groningen, Netherlands
Titolo Testata:
JOURNAL OF CATARACT AND REFRACTIVE SURGERY
fascicolo: 6, volume: 27, anno: 2001,
pagine: 928 - 933
SICI:
0886-3350(200106)27:6<928:ILDFTN>2.0.ZU;2-J
Fonte:
ISI
Lingua:
ENG
Soggetto:
BILATERAL CONGENITAL CATARACTS; RABBIT EYES; AFTER-CATARACT; OCULAR GROWTH; AXIAL LENGTH; CAPSULAR BAG; IMPLANTATION; SURGERY; PHACOEMULSIFICATION; COMPLICATIONS;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Citazioni:
23
Recensione:
Indirizzi per estratti:
Indirizzo: Lundvall, A St Eriks Eye Hosp, Karolinska Inst, Polhemsgatan 50, SE-11282 Stockholm, Sweden St Eriks Eye Hosp Polhemsgatan 50 Stockholm Sweden SE-11282 n
Citazione:
A. Lundvall et al., "Intraocular lens designed for the newborn infant eye", J CAT REF S, 27(6), 2001, pp. 928-933

Abstract

Purpose: To evaluate the effects of an intraocular lens (IOL) designed forsmall eyes after clear lens extraction in an animal model. Setting: St. Erik's Eye Hospital, Karolinska Institute, Stockholm, Sweden. Methods: Clear lens extraction was performed in both eyes in 19 3-week-oldrabbits. In 1 randomly selected eye of each rabbit, a small IOL with long haptics was implanted. Axial length, corneal thickness, corneal diameter, and intraocular pressure were measured preoperatively and every month for 6 months postoperatively. Six months after surgery, the wet mass of the after-cataract was determined. Results: The IOL remained well centered in all eyes. Four animals developed severe glaucoma in 5 eyes (3 aphakic and 2 pseudophakic) soon after surgery and were excluded. In the 15 animals completing the study, signs of glaucoma evolved in 7 animals (5 aphakic and 4 pseudophakic eyes). In aphakic eyes, significant amounts of after-cataract (median 250 mg) developed in all15 surviving animals. In pseudophakic 1 eyes, small amounts of after-cataract (median 30 mg) were present. During the first 2 months after surgery, ocular growth was less in pseudophakic eyes than in aphakic eyes. Conclusions: Results indicate that implantation of a down-sized IOL with long haptics in small eyes is safe. Considerable less after-cataract was found in eyes with the IOL than in aphakic control eyes. J Cataract Refract Surg 2001; 27:928-933 (C) 2001 ASCRS and ESCRS.