Catalogo Articoli (Spogli Riviste)

OPAC HELP

Titolo:
A compact optical system for multi-determination of biochemical oxygen demand using disposable strips
Autore:
Yoshida, N; McNiven, SJ; Yoshida, A; Morita, T; Nakamura, H; Karube, I;
Indirizzi:
Univ Tokyo, Adv Sci & Technol Res Ctr, Meguro Ku, Tokyo 1538904, Japan Univ Tokyo Tokyo Japan 1538904 Res Ctr, Meguro Ku, Tokyo 1538904, Japan Akebono Res & Dev Ctr Ltd, Kasukabe, Saitama 3440063, Japan Akebono Res & Dev Ctr Ltd Kasukabe Saitama Japan 3440063 a 3440063, Japan
Titolo Testata:
FIELD ANALYTICAL CHEMISTRY AND TECHNOLOGY
fascicolo: 5, volume: 5, anno: 2001,
pagine: 222 - 227
SICI:
1086-900X(2001)5:5<222:ACOSFM>2.0.ZU;2-Y
Fonte:
ISI
Lingua:
ENG
Soggetto:
MICROBIAL FUEL-CELLS; DISSOLVED-OXYGEN; BIOSENSOR; SENSOR; BOD;
Keywords:
biochemical oxygen demand (BOD); immobilized microorganisms; disposable sensor; light emitting diode; Pseudomonas fluorescens; 2,6-dichlorophenolindophenol (DCIP);
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Agriculture,Biology & Environmental Sciences
Physical, Chemical & Earth Sciences
Engineering, Computing & Technology
Citazioni:
27
Recensione:
Indirizzi per estratti:
Indirizzo: Karube, I Univ Tokyo, Adv Sci & Technol Res Ctr, Meguro Ku, 4-6-1 Komaba, Tokyo 1538904, Japan Univ Tokyo 4-6-1 Komaba Tokyo Japan 1538904 okyo 1538904, Japan
Citazione:
N. Yoshida et al., "A compact optical system for multi-determination of biochemical oxygen demand using disposable strips", FIELD A C T, 5(5), 2001, pp. 222-227

Abstract

A compact optical device and disposable strips for the simultaneous determination of the biochemical oxygen demand (BOD) of multiple samples have been developed. The compact optical device was constructed using three pairs of light emitting diodes (LEDs) and silicon photodiodes (SI-PDs), and the disposable strips were fabricated using inexpensive, transparent polycarbonate plates. Pseudomonas fluorescens bacteria were immobilized in a layer at the bottom of each reaction cell on the sensor strip using a photocrosslinkable resin (ENT-2000). Using the redox electron acceptor 2,6-dichlorophenolindophenol sodium salt as the chromophore, a linear relationship was observed between the response of the Si-PDs and the BOD value of Organization of Economic Cooperation synthetic wastewater. Real samples from a wastewater treatment plant and a kitchen in our factory were examined, and good correlations were observed between the BOD values derived using this system and those determined by the conventional BOD5 method. In addition, in spite of thesensor response decreasing to approximately half its initial value after 2weeks, the correlation coefficients (r(2)) of calibration curves remained above 0.9 upon storage of the strips in 0.1 M NaCl solution at 4 degreesC for up to 6 weeks. In conclusion, this system is transportable and compact as well as being simple to operate and suitable for rapid, on-site measurements. (C) 2001 John Wiley & Sons, Inc.

ASDD Area Sistemi Dipartimentali e Documentali, Università di Bologna, Catalogo delle riviste ed altri periodici