Catalogo Articoli (Spogli Riviste)

OPAC HELP

Titolo:
An enhanced method for left ventricular volume and ejection fraction by triggered harmonic contrast echocardiography
Autore:
Hirooka, K; Yasumura, Y; Tsujita, Y; Hanatani, A; Nakatani, S; Miyatake, K; Yamagishi, M;
Indirizzi:
Osaka Natl Hosp, Div Cardiovasc, Chuo Ku, Osaka 5400006, Japan Osaka Natl Hosp Osaka Japan 5400006 ovasc, Chuo Ku, Osaka 5400006, Japan Natl Cardiovasc Ctr, Cardiol Div Med, Osaka, Japan Natl Cardiovasc Ctr Osaka Japan vasc Ctr, Cardiol Div Med, Osaka, Japan
Titolo Testata:
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING
fascicolo: 4, volume: 17, anno: 2001,
pagine: 253 - 261
SICI:
0167-9899(200108)17:4<253:AEMFLV>2.0.ZU;2-1
Fonte:
ISI
Lingua:
ENG
Soggetto:
TWO-DIMENSIONAL ECHOCARDIOGRAPHY; CROSS-SECTIONAL ECHOCARDIOGRAPHY; DOBUTAMINE STRESS ECHOCARDIOGRAPHY; ENDOCARDIAL BORDER DEFINITION; SONICATED DEXTROSE ALBUMIN; RADIONUCLIDE ANGIOGRAPHY; 2-DIMENSIONAL ECHOCARDIOGRAPHY; MYOCARDIAL-INFARCTION; ULTRASOUND; ALBUNEX;
Keywords:
contrast media; echocardiography; volume determination;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Citazioni:
30
Recensione:
Indirizzi per estratti:
Indirizzo: Hirooka, K Osaka Natl Hosp, Div Cardiovasc, Chuo Ku, 2-1-14 Hoenzaka, Osaka 5400006, Japan Osaka Natl Hosp 2-1-14 Hoenzaka Osaka Japan 5400006 006, Japan
Citazione:
K. Hirooka et al., "An enhanced method for left ventricular volume and ejection fraction by triggered harmonic contrast echocardiography", INT J CARDI, 17(4), 2001, pp. 253-261

Abstract

To elucidate the validity and reproducibility of the use of intravenous echo-contrast agent in the evaluation of left ventricular (LV) performance, we measured LV volume and ejection fraction (EF) in 42 patients with triggered harmonic contrast imaging (THCI), compared with continuous harmonic imaging without contrast agent (CHI) and with cineventriculography (CVG). In 10of 42 patients, THCI improved LV border delineation which could not be obtained even with CHI. LV end-diastolic, end-systolic volumes and EF by both CHI and THCI correlated well with those by CVG. Although LV volumes are underestimated, THCI lessened the mean differences to about in half, compared with CHI. The observer variabilities obtained using THCI were smaller than those by CHI. These results indicate the validity of LV enhancement and themeasurement of EF using THCI. We suggest that this method noninvasively provides more accurate LV systolic function with the acceptable reproducibility.