T2-weighted MRI of the female pelvis: Comparison of breath-hold fast-recovery fast spin-echo and nonbreath-hold fast spin-echo sequences
Autore:
Masui, T; Katayama, M; Kobayashi, S; Sakahara, H; Ito, T; Nozaki, A;
Indirizzi:
Seirei Hamamatsu Gen Hosp, Dept Radiol, Hamamatsu, Shizuoka 4308558, JapanSeirei Hamamatsu Gen Hosp Hamamatsu Shizuoka Japan 4308558 4308558, Japan
Titolo Testata:
JOURNAL OF MAGNETIC RESONANCE IMAGING
fascicolo: 6, volume: 13, anno: 2001,
pagine: 930 - 937
SICI:
1053-1807(200106)13:6<930:TMOTFP>2.0.ZU;2-G
Fonte:
ISI
Lingua:
ENG
Soggetto:
ENDOMETRIAL CARCINOMA; JUNCTIONAL ZONE; DIAGNOSIS; UTERUS; ADENOMYOSIS; LEIOMYOMA; ABDOMEN; DIFFERENTIATION;
Keywords:
pelvis; magnetic resonance (MR); rapid imaging; uterus; ovary;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Citazioni:
22
Recensione:
Indirizzi per estratti:
Indirizzo: Masui, T Seirei Hamamatsu Gen Hosp, Dept Radiol, 2-12-12 Sumiyoshi, Hamamatsu, Shizuoka 4308558, Japan Seirei Hamamatsu Gen Hosp 2-12-12 Sumiyoshi Hamamatsu Shizuoka Japan 4308558
Citazione:
T. Masui et al., "T2-weighted MRI of the female pelvis: Comparison of breath-hold fast-recovery fast spin-echo and nonbreath-hold fast spin-echo sequences", J MAGN R I, 13(6), 2001, pp. 930-937

Abstract

In 49 patients who had pelvic abnormalities, breath-hold T2-weighted fast-recovery (FR)-fast spin-echo (FSE) (imaging time = 24 sec) and nonbreath-hold FSE MR images (2 min 8 sec) were compared qualitatively (on a four-pointscale) and quantitatively (using signal-to-noise ratios (SNRs) and contrast ratios (\ SIs of the lesions-SIs of the myometrium \ /SIs of the myometrium)). Motion artifacts were reduced on breath-hold FR-FSE (3.8:3.2 = breath-hold FSE:nonbreath-hold FSE, P < 0.01) and image quality was comparable (3.8:3.7, NS). In all patients, pathology (leiomyoma [N = 26], adenomyosis [N= 10], endometrial carcinoma [N = 8], and ovarian cystic lesions [N = 21])was recognized with comparable lesion conspicuity (3.8:3.7, NS) and betterdelineation of the structures (3.9:3.6, P < 0.05) on the FR-FSE images. There was no significant difference in contrast ratios, although SNRs (e.g., myometrium 18.3:25.8, P < 0.01) were better and the uterine zonal anatomy was recognized better on the nonbreath-hold FSE (3.4:3.7, P < 0.05). These differences did not affect the diagnosis. Breath-hold FR-FSE provides the benefits of motionless Imaging and a short examination time, although lower SNRs were noted. J. Magn. Reson. Imaging 2001;13:930-937. (C) 2001 Wiley-Liss, Inc.