Comparative studies of the dW/dt effect in the net heating power for ignition analyses
Autore:
Mitarai, O; Honda, T; Nishitani, T; Muraoka, K;
Indirizzi:
Kyushu Tokai Univ, Sch Engn, Kumamoto 8628652, Japan Kyushu Tokai Univ Kumamoto Japan 8628652 h Engn, Kumamoto 8628652, Japan Hitachi Ltd, Hitachi, Ibaraki 3191221, Japan Hitachi Ltd Hitachi Ibaraki Japan 3191221 Hitachi, Ibaraki 3191221, Japan Japan Atom Energy Res Inst, Naka Fus Res Inst, Ibaraki, Osaka, Japan JapanAtom Energy Res Inst Ibaraki Osaka Japan st, Ibaraki, Osaka, Japan Kyushu Univ, Interdisciplinary Grad Sch Engn Sci, Dept Energy Convers, Kasuga, Fukuoka 8168580, Japan Kyushu Univ Kasuga Fukuoka Japan 8168580 , Kasuga, Fukuoka 8168580, Japan
Titolo Testata:
FUSION ENGINEERING AND DESIGN
fascicolo: 4, volume: 55, anno: 2001,
pagine: 477 - 500
SICI:
0920-3796(200109)55:4<477:CSOTDE>2.0.ZU;2-7
Fonte:
ISI
Lingua:
ENG
Soggetto:
TOKAMAK REACTOR; BURN CONTROL; FUSION-REACTOR; OPERATION; ITER; PERFORMANCE; DIAGNOSTICS; TRANSITION; PLASMAS;
Keywords:
dW/dt effect; net heating power; ignition analysis;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Engineering, Computing & Technology
Citazioni:
30
Recensione:
Indirizzi per estratti:
Indirizzo: Mitarai, O Kyushu Tokai Univ, Sch Engn, 9-1-1 Toroku, Kumamoto 8628652, Japan Kyushu Tokai Univ 9-1-1 Toroku Kumamoto Japan 8628652 2, Japan
Citazione:
O. Mitarai et al., "Comparative studies of the dW/dt effect in the net heating power for ignition analyses", FUSION ENG, 55(4), 2001, pp. 477-500

Abstract

We compare two cases with and without subtraction of dW/dt in the net heating power after the high confinement mode transition (H-transition) and study the effects of dW/dt on zero-dimensional ignition analyses in various ignition phases in a deuterium-tritium (D-T) tokamak reactor including International Thermonuclear Experimental Reactor (ITER). Subtraction of dW/dt from the net heating power after the H-transition as done in H-mode power threshold analyses results in a wrong control action in feedback control duringthe confinement factor increment and abnormal behaviors in operation phases such as fusion power ramp-up, steady state, and shutdown phases in a reactor. As subtraction of dW/dt in the L-mode phase is to describe the delay time effect of the heating power to the plasma edge, we conclude that dW/dt should not be subtracted from the net heating power after the H-transition in the zero-dimensional approach. This is because that the H-mode is determined by the net heating power to the plasma edge both before and after the H-transition, but not by the plasma conduction loss power out of the plasmaedge. (C) 2001 Elsevier Science B.V. All rights reserved.