Catalogo Articoli (Spogli Riviste)

OPAC HELP

Titolo:
Haemodynamic, invasive and echocardiographic monitoring in the hypertensive parturient
Autore:
Young, P; Johanson, R;
Indirizzi:
N Staffordshire Matern Unit, Stoke On Trent ST4 6QG, Staffs, England N Staffordshire Matern Unit Stoke On Trent Staffs England ST4 6QG England
Titolo Testata:
BEST PRACTICE & RESEARCH IN CLINICAL OBSTETRICS & GYNAECOLOGY
fascicolo: 4, volume: 15, anno: 2001,
pagine: 605 - 622
SICI:
1521-6934(200108)15:4<605:HIAEMI>2.0.ZU;2-C
Fonte:
ISI
Lingua:
ENG
Soggetto:
PREGNANCY-INDUCED HYPERTENSION; PULMONARY-ARTERY CATHETER; CAPILLARY WEDGE PRESSURE; CENTRAL VENOUS-PRESSURE; CRITICALLY ILL PATIENTS; SEVERE PRE-ECLAMPSIA; SEVERE PREECLAMPSIA; HEMODYNAMIC OBSERVATIONS; CARDIAC-OUTPUT; CARDIOVASCULAR ALTERATIONS;
Keywords:
pregnancy complications; pre-eclampsia; haemodynamics; echocardiography; catheter; Swan-Ganz;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Citazioni:
57
Recensione:
Indirizzi per estratti:
Indirizzo: Young, P N Staffordshire Matern Unit, Newcastle Rd, Stoke On Trent ST4 6QG, Staffs,England N Staffordshire Matern Unit Newcastle Rd Stoke On Trent Staffs England ST4 6QG
Citazione:
P. Young e R. Johanson, "Haemodynamic, invasive and echocardiographic monitoring in the hypertensive parturient", BEST P R CL, 15(4), 2001, pp. 605-622

Abstract

Aim. To determine the clinical usefulness of invasive and non-invasive haemodynamic assessment in pre-eclampsia. Method. A systematic review of the literature was undertaken, using a MEDLINE electronic search using a combination of MESH headings and textwords. Over 1500 abstracts were perused; we obtained 156 full papers that were related to the subject matter. Of the full papers, 55 yielded relevant information. Hand-searching the reference lists of the retrieved papers completed the search. Results. There are no data from randomized controlled clinical trials illustrating the clinical usefulness of pulmonary artery catheters or echocardiographic techniques in hypertensive pregnancy. There are a wealth of data illustrating the haemodynamic profiles of both untreated and treated pre-eclamptic women. Data are also available comparing right heart and left heart filling pressures, demonstrating a relatively poor correlation between the two values. The clinical impact of either measurement is unclear. Data are available illustrating the correlation between echocardiographic techniques and pulmonary artery catheterization.

ASDD Area Sistemi Dipartimentali e Documentali, Università di Bologna, Catalogo delle riviste ed altri periodici
Documento generato il 22/01/20 alle ore 12:24:14