Observer reproducibility in computed tomography of oro- and hypopharyngealcarcinomas
Autore:
Keberle, M; Kenn, W; Muller, H; Hahn, D;
Indirizzi:
Univ Wurzburg, Inst Rontgendiagnost, D-97080 Wurzburg, Germany Univ Wurzburg Wurzburg Germany D-97080 agnost, D-97080 Wurzburg, Germany
Titolo Testata:
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN
fascicolo: 7, volume: 173, anno: 2001,
pagine: 583 - 590
SICI:
1438-9029(200107)173:7<583:ORICTO>2.0.ZU;2-0
Fonte:
ISI
Lingua:
GER
Soggetto:
SPIRAL CT; CLINICAL-VALUE; ORAL CAVITY; TUMORS; INTEROBSERVER; VARIABILITY; INTRAOBSERVER; OROPHARYNX; LARYNX; KAPPA;
Keywords:
pharynx; pharynx, neoplasms; computed tomography;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Citazioni:
27
Recensione:
Indirizzi per estratti:
Indirizzo: Keberle, M Univ Wurzburg, Inst Rontgendiagnost, Josef Schneider Str 2, D-97080 Wurzburg, Germany Univ Wurzburg Josef Schneider Str 2 Wurzburg Germany D-97080 y
Citazione:
M. Keberle et al., "Observer reproducibility in computed tomography of oro- and hypopharyngealcarcinomas", ROFO-F RONT, 173(7), 2001, pp. 583-590

Abstract

Purpose: To evaluate the inter- and intraobserver reproducibilities of computed tomography (CT) in patients with oro- and hypopharyngeal carcinomas. Methods: Two independent readers interpreted the CT images of 41 patients with hypopharyngeal carcinomas, 45 patients with oropharyngeal carcinomas, and 23 patients without a tumor. All relevant subregional anatomic structures were evaluated for the presence of tumor infiltration. Statistical analysis was done by using Cohen's kappa and the Wilcoxon test; subregional prevalences, sensitivities, and specificities were also determined. Results: Mostly, especially for clinically relevant subregions, moderate and substantial inter- and intraobserver reproducibilities were determined (range of the determined kappa values: 0.25 - 1.00). The kappa values of the intraobserver reproducibilities of both readers were not significantly different (P = 0.20). The kappa values of the intraobserver reproducibilities were in almost all the cases higher than the respective kappa values of the interobserver reproducibility. Conclusion: CT of oro- and hypopharyngeal carcinomas canbe interpreted with clinically acceptable variability. A higher agreement can be achieved if repeated interpretation is done by a single person.