Catalogo Articoli (Spogli Riviste)

OPAC HELP

Titolo:
Experimental evaluation of a modified amplatzer duct occluder
Autore:
Kong, HF; Gu, XP; Bass, JL; Titus, J; Urness, M; Kim, TH; Hunter, DW;
Indirizzi:
Univ Minnesota, Dept Radiol, Minneapolis, MN 55455 USA Univ Minnesota Minneapolis MN USA 55455 Radiol, Minneapolis, MN 55455 USA AGA Med Inc, Golden Valley, MN USA AGA Med Inc Golden Valley MN USAAGA Med Inc, Golden Valley, MN USA Univ Minnesota, Dept Pediat Cardiol, Minneapolis, MN USA Univ Minnesota Minneapolis MN USA pt Pediat Cardiol, Minneapolis, MN USA United Hosp, Jesse E Edwards Regist Cardiovasc Dis, Dept Pathol, St Paul, MN USA United Hosp St Paul MN USA Cardiovasc Dis, Dept Pathol, St Paul, MN USA
Titolo Testata:
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS
fascicolo: 4, volume: 53, anno: 2001,
pagine: 571 - 576
SICI:
1522-1946(200108)53:4<571:EEOAMA>2.0.ZU;2-U
Fonte:
ISI
Lingua:
ENG
Soggetto:
TRANSCATHETER OCCLUSION; COIL OCCLUSION; FOLLOW-UP; CATHETER CLOSURE; ARTERIOSUS; DEVICE; HEMOLYSIS;
Keywords:
patent ductus arteriosus; interventional embolization; prosthesis; shunt;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Citazioni:
31
Recensione:
Indirizzi per estratti:
Indirizzo: Kong, HF Univ Minnesota, Dept Radiol, MMC 292,420 Delaware St SE, Minneapolis, MN 55455 USA Univ Minnesota MMC 292,420 Delaware St SE Minneapolis MN USA 55455
Citazione:
H.F. Kong et al., "Experimental evaluation of a modified amplatzer duct occluder", CATHET C IN, 53(4), 2001, pp. 571-576

Abstract

The purpose of this study was to evaluate a new device specifically designed for patent ductus arteriosus (PDA) occlusion based on PDA anatomy. Percutaneous closure of aortopulmonary shunts was attempted in 10 dogs. Shunts were surgically created in the location and orientation of PDA. The occlusion prosthesis consisted of a cylindrical frame filled with polyester and a 32 degrees angled retention disk. The delivery system of the device includeda 6 Fr thin-walled Teflon introducing sheath, an antirotating delivery catheter, and cable. Complete occlusion of the shunt was obtained in nine animals. One animal died before device placement. Temporary hemolysis occurred in one dog after device placement. The disk of device was completely covered by smooth glistening neoendothelium at 1-3 months postmortem examination. None of the devices protruded into the lumen of the aorta. The device is an improvement over the standard Amplatzer duct occludes. The angled retention disk lies flatly against the aortic wall, avoiding turbulence or an aortic pressure gradient. (C) 2001 Wiley-Liss, Inc.

ASDD Area Sistemi Dipartimentali e Documentali, Università di Bologna, Catalogo delle riviste ed altri periodici