Titolo: Early clinical experience with the 6 French Angio-Seal (TM) device: Immediate closure of femoral puncture sites after diagnostic and interventional coronary procedures
Autore: Eggebrecht, H; Haude, M; von Birgelen, C; Woertgen, U; Schmermund, A; Baumgart, D; Kaiser, C; Naber, CK; Kroeger, K; Erbel, R;
- Indirizzi:
- Univ Hosp Essen, Cardiac Catheterizat Lab, Dept Cardiol, Ctr Internal Med,D-45122 Essen, Germany Univ Hosp Essen Essen Germany D-45122 nternal Med,D-45122 Essen, Germany Univ Hosp Essen, Dept Angiol, Essen, Germany Univ Hosp Essen Essen Germany v Hosp Essen, Dept Angiol, Essen, Germany
- Titolo Testata:
- CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS
fascicolo: 4,
volume: 53,
anno: 2001,
pagine: 437 - 442
- SICI:
- 1522-1946(200108)53:4<437:ECEWT6>2.0.ZU;2-T
- Fonte:
- ISI
- Lingua:
- ENG
- Soggetto:
- ARTERIAL ACCESS SITES; CARDIAC-CATHETERIZATION; VASCULAR COMPLICATIONS; INITIAL EXPERIENCE; ANGIO-SEAL; ANGIOPLASTY; HEMOSTASIS; TRIAL; FEASIBILITY; COLLAGEN;
- Keywords:
- vascular access complications; catheterization; closure device; femoral; bleeding;
- Tipo documento:
- Article
- Natura:
- Periodico
- Settore Disciplinare:
- Clinical Medicine
- Citazioni:
- 26
- Recensione:
- Indirizzi per estratti:
- Indirizzo: Eggebrecht, H Univ Hosp Essen, Cardiac Catheterizat Lab, Dept Cardiol, CtrInternal Med,Hufelandstr 55, D-45122 Essen, Germany Univ Hosp Essen Hufelandstr 55 Essen Germany D-45122 ermany
-
-
-
- Citazione:
- H. Eggebrecht et al., "Early clinical experience with the 6 French Angio-Seal (TM) device: Immediate closure of femoral puncture sites after diagnostic and interventional coronary procedures", CATHET C IN, 53(4), 2001, pp. 437-442
Abstract
The objective of this study was to assess the early safety and efficacy ofthe novel 6 Fr Angio-Seal device for routine clinical use after diagnosticcardiac catheterization and coronary angioplasty. In a prospective study, we used the 6 Fr Angio-Seal (TM) device in 180 consecutive patients (131 male, 49 female, mean age 60.7 years) for closure of femoral arterial puncture sites immediately after diagnostic (n = 108) or interventional (n = 72) coronary procedures independent of the coagulation status. All patients weremonitored for 24 hr after the procedure and followed for 30 days. The closure device was successfully deployed in 95.4% after diagnostic catheterization versus 98.6% after coronary angioplasty (P = 0.963). Immediate hemostasis was achieved in 91.5% versus 90.1% of the patients (P = 0.993). Major complications were observed 1.9% versus 2.8% of the patients (P = 0.885). During 30-day follow-up, no late events or complications were reported. The 6 Fr Angio-Seal (TM) device is a safe and effective device that allows for immediate closure of femoral puncture sites after both diagnostic and interventional procedures with a low rate of major complications. (C) 2001 Wiley-Liss, Inc.