Catalogo Articoli (Spogli Riviste)

OPAC HELP

Titolo:
Percutaneous transfemoral placement of a new flexible stent-graft into thethoracic aorta followed by a percutaneous suture-mediated closure of the access site - Initial experience.
Autore:
Manke, C; Kobuch, R; Lenhart, M; Strotzer, M; Merk, J; Birnbaum, F; Feuerbach, S; Link, J;
Indirizzi:
Klinikum Univ Regensburg, Inst Rontgendiagnost, D-93042 Regensburg, Germany Klinikum Univ Regensburg Regensburg Germany D-93042 Regensburg, Germany Klinikum Univ Regensburg, Klin & Poliklin Herz Thorax & Herznahe Gefasschir, Regensburg, Germany Klinikum Univ Regensburg Regensburg Germany sschir, Regensburg, Germany
Titolo Testata:
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN
fascicolo: 5, volume: 173, anno: 2001,
pagine: 442 - 447
SICI:
1438-9029(200105)173:5<442:PTPOAN>2.0.ZU;2-R
Fonte:
ISI
Lingua:
GER
Soggetto:
VASCULAR-SURGERY; ANEURYSMS; REPAIR; RECONSTRUCTION; DISSECTION; DRAINAGE; WOUNDS;
Keywords:
aorta, aneurysm; aorta, dissection; aorta, stents and prostheses; interventional procedure;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Citazioni:
12
Recensione:
Indirizzi per estratti:
Indirizzo: Manke, C Klinikum Univ Regensburg, Inst Rontgendiagnost, Franz Josef Strauss Allee 11, D-93042 Regensburg, Germany Klinikum Univ Regensburg Franz Josef Strauss Allee 11 Regensburg Germany D-93042
Citazione:
C. Manke et al., "Percutaneous transfemoral placement of a new flexible stent-graft into thethoracic aorta followed by a percutaneous suture-mediated closure of the access site - Initial experience.", ROFO-F RONT, 173(5), 2001, pp. 442-447

Abstract

Purpose: To evaluate the transfemoral placement of a new, flexible stent-graft into the thoracic aorta and the suture-mediated closure of the femoralaccess. Patients and Methods: Five patients were treated endovascularly with a stent-graft for an aneurysm (n=3) or acute dissection (n=2) of the thoracic aorta via a femoral 24 F sheath. The femoral access site was closed with two suture-mediated closure devices after placement of the stent-graft. Results: The aneurysm or the false lumen was excluded from perfusion by the placement of the stent-graft in all patients. Hemostasis at the femoral access site was successful in all patients with the percutaneous suture device. A minor stenosis of the femoral artery was found angiographically in four patients after suture-mediated closure. Besides a reversible renal failure due to the medically induced hypotension for the treatment of an acutelyruptured aneurysm, no complications resulted from the stent-graft placement or the percutaneous suture. Conclusion: The percutaneous transfemoral placement of stent-grafts in the thoracic aorta using a suture-mediated closure of the access site is technically feasible. Long-term results of the technique have to be awaited.

ASDD Area Sistemi Dipartimentali e Documentali, Università di Bologna, Catalogo delle riviste ed altri periodici
Documento generato il 06/04/20 alle ore 11:48:51