Catalogo Articoli (Spogli Riviste)

OPAC HELP

Titolo:
Comparison between liquid chromatography-time-of-flight mass spectrometry and selected reaction monitoring liquid chromatography-mass spectrometry for quantitative determination of idoxifene in human plasma
Autore:
Zhang, HW; Henion, J;
Indirizzi:
Cornell Univ, New York State Coll Vet Med, Ithaca, NY 14850 USA Cornell Univ Ithaca NY USA 14850 State Coll Vet Med, Ithaca, NY 14850 USA
Titolo Testata:
JOURNAL OF CHROMATOGRAPHY B
fascicolo: 1, volume: 757, anno: 2001,
pagine: 151 - 159
SICI:
1387-2273(20010605)757:1<151:CBLCMS>2.0.ZU;2-K
Fonte:
ISI
Lingua:
ENG
Soggetto:
96-WELL PLATE FORMAT; BREAST-CANCER; LC-MS/MS; EXTRACTION; TAMOXIFEN; SAMPLES;
Keywords:
iodoxifene;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Life Sciences
Citazioni:
25
Recensione:
Indirizzi per estratti:
Indirizzo: Henion, J Cornell Univ, New York State Coll Vet Med, 927 Warren Dr, Ithaca, NY 14850USA Cornell Univ 927 Warren Dr Ithaca NY USA 14850 haca, NY 14850USA
Citazione:
H.W. Zhang e J. Henion, "Comparison between liquid chromatography-time-of-flight mass spectrometry and selected reaction monitoring liquid chromatography-mass spectrometry for quantitative determination of idoxifene in human plasma", J CHROMAT B, 757(1), 2001, pp. 151-159

Abstract

This study compares HPLC electrospray time-of-flight mass spectrometry andselected reaction monitoring (SRM) LC-MS for high throughput quantitative determination of a small molecule drug in biological samples. A high throughput LC-MS method was developed for quantitatative determination of idoxifene in human plasma and the evaluation was accomplished with the cross-validation of the developed LC-MS method between the time-of-flight mass spectrometer, and a triple quadrupole mass spectrometer operated in the SRM mode. A simple one-step semi-automated 96-well liquid-liquid extraction procedurewas used to prepare 96 samples in approximately 30 min and a rapid gradient was used to shorten the LC run time. Time-of-flight mass spectrometry provides acquisition of full-scan mass spectra and extracted ion current chromatograms, which may be extracted from the total ion current chromatogram for peak area determination. The limit of quantitation for idoxifene in humanplasma obtained with the time-of-flight mass spectrometer was 5 ng/ml based on 100-mul aliquots of human plasma, and the linear dynamic range was from 5 ng/ml to 2000 ng/ml. The quantitative LC-MS results from the time-of-flight mass spectrometer demonstrated that precision did not exceed 7.1% and accuracy did not exceed 1.7% with reference to quality control samples at three concentration levels in replicates of six. In contrast, the limit of quantitation for idoxifene in human plasma using a tandem triple quadrupole mass spectrometer was 0.5 ng/ml with a linear dynamic range to 1000 ng/ml. The results from the triple quadrupole instrument show that the precision did not exceed 2.2% and accuracy did not exceed 2.9%. The overall results suggest time-of-flight mass spectrometry may be a viable technique for high throughput bioanalytical work for the quantitative determination of a representative small molecule drug in the low ng/ml range in human plasma. (C) 2001 Elsevier Science BN, All rights reserved.