Comparison of scientific calipers and computer-enabled CT review for the measurement of skull base and craniomaxillofacial dimensions
Autore:
Citardi, MJ; Herrmann, B; Hollenbeak, CS; Stack, BC; Cooper, M; Bucholz, RD;
Indirizzi:
Cleveland Clin Fdn, Dept Otolaryngol & Communicat Disorders, Cleveland, OH44195 USA Cleveland Clin Fdn Cleveland OH USA 44195 sorders, Cleveland, OH44195 USA St Louis Univ, Sch Med, Dept Otolaryngol Head & Neck Surg, St Louis, MO USA St Louis Univ St Louis MO USA aryngol Head & Neck Surg, St Louis, MO USA St Louis Univ, Sch Med, Dept Anat, St Louis, MO USA St Louis Univ St Louis MO USA Univ, Sch Med, Dept Anat, St Louis, MO USA St Louis Univ, Sch Med, Dept Neurosurg, St Louis, MO USA St Louis Univ StLouis MO USA Sch Med, Dept Neurosurg, St Louis, MO USA Penn State Univ, Sch Med, Dept Otolaryngol Head & Neck Surg, Hershey, PA USA Penn State Univ Hershey PA USA aryngol Head & Neck Surg, Hershey, PA USA
Titolo Testata:
SKULL BASE-AN INTERDISCIPLINARY APPROACH
fascicolo: 1, volume: 11, anno: 2001,
pagine: 5 - 11
SICI:
1531-5010(2001)11:1<5:COSCAC>2.0.ZU;2-1
Fonte:
ISI
Lingua:
ENG
Soggetto:
HEAD FILM MEASUREMENTS; CEPHALOMETRIC ANALYSIS; SYSTEM; RELIABILITY; SURGERY;
Keywords:
computer-aided surgery; 3D CT model; cephalometrics;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Citazioni:
14
Recensione:
Indirizzi per estratti:
Indirizzo: Citardi, MJ Cleveland Clin Fdn, Dept Otolaryngol & Communicat Disorders, 9500 Euclid Ave,Desk A71, Cleveland, OH 44195 USA Cleveland Clin Fdn 9500 Euclid Ave,Desk A71 Cleveland OH USA 44195
Citazione:
M.J. Citardi et al., "Comparison of scientific calipers and computer-enabled CT review for the measurement of skull base and craniomaxillofacial dimensions", SKULL BASE, 11(1), 2001, pp. 5-11

Abstract

Traditionally, cadaveric studies and plain-film cephalometrics provided information about craniomaxillofacial proportions and measurements; however, advances in computer technology now permit software-based review of computed tomography (CT)-based models. Distances between standardized anatomic points were measured on five dried human skulls with standard scientific calipers (Geneva Gauge, Albany, NY) and through computer workstation (StealthStation 2.6.4, Medtronic Surgical Navigation Technology, Louisville, CO) review of corresponding CT scans. Differences in measurements between the caliper and CT model were not statistically significant for each parameter. Measurements obtained by computer workstation CT review of the cranial skull base are an accurate representation of actual bony anatomy. Such information has important implications for surgical planning and clinical research.