Measurement of joint space width in hip osteoarthritis: influence of jointpositioning and radiographic procedure
Autore:
Auleley, GR; Duche, A; Drape, JL; Dougados, M; Ravaud, P;
Indirizzi:
Univ Paris V Rene Descartes, Fac Med, CHU Cochin Port Royal, Hop Cochin,Clin Rhumatol, F-75014 Paris, France Univ Paris V Rene Descartes Paris France F-75014 , F-75014 Paris, France Univ Paris V Rene Descartes, Fac Med, CHU Cochin Port Royal, Hop Cochin,Serv Radiol B, F-75014 Paris, France Univ Paris V Rene Descartes Paris France F-75014 , F-75014 Paris, France Univ Paris 07, Fac Med Xavier Bichat, Paris, France Univ Paris 07 Paris France ris 07, Fac Med Xavier Bichat, Paris, France Hop Bichat Claude Bernard, Dept Clin Epidemiol & Biostat, F-75877 Paris, France Hop Bichat Claude Bernard Paris France F-75877 at, F-75877 Paris, France
Titolo Testata:
RHEUMATOLOGY
fascicolo: 4, volume: 40, anno: 2001,
pagine: 414 - 419
SICI:
1462-0324(200104)40:4<414:MOJSWI>2.0.ZU;2-X
Fonte:
ISI
Lingua:
ENG
Soggetto:
RADIOLOGICAL PROGRESSION; ACETABULAR DYSPLASIA; CARTILAGE THICKNESS; KNEE OSTEOARTHRITIS; DEFINITION; AGREEMENT;
Keywords:
hip; joint space width; osteoarthritis; radiographic measurement; smallest delectable difference;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Citazioni:
38
Recensione:
Indirizzi per estratti:
Indirizzo: Ravaud, P Univ Paris V Rene Descartes, Fac Med, CHU Cochin Port Royal, HopCochin,Clin Rhumatol, 27 Rue Faubourg St Jacques, F-75014 Paris, France Univ Paris V Rene Descartes 27 Rue Faubourg St Jacques Paris France F-75014
Citazione:
G.R. Auleley et al., "Measurement of joint space width in hip osteoarthritis: influence of jointpositioning and radiographic procedure", RHEUMATOLOG, 40(4), 2001, pp. 414-419

Abstract

Objectives. We assessed the influence of patient positioning and radiographic procedure, and defined a smallest detectable difference (SDD) in hip osteoarthritis (OA). Methods. OA hip patients each had a standardized pelvic radiograph and, 5 min later. a modified pelvic radiograph with the feet internally rotated 5 degrees (part 1 of the study), the X-ray beam centred on the umbilicus (part 2), or another standardized pelvic radiograph (part 3). Results. Corresponding mean differences in joint space width (JSW) measurements (limits of agreement) between views were + 0.03 (- 0.53 to + 0.59), -0.31 (- 1.15 to + 0.53) and - 0.02 (- 0.48 to + 0.44) mm. The two views differed significantly in mean JSW in part 2 of the study (P = 1.6 x 10(-4)).but not in part I (P = 0.375) and part 3 (P = 0.580). The SDD estimate was0.46 mm. Conclusions. Modifying the X-ray beam and foot rotation increases variability in JSW measurements. Use of urograms to evaluate radiological progression should be avoided. A change greater than 0.46 mm could define radiological hip OA progression.