Titolo:
Reproducibility of ductus venosus Doppler flow measurements at 11-14 weeksof gestation
Autore:
Prefumo, F; De Biasio, P; Venturini, PL;
Indirizzi:
Univ Genoa, Ist Giannina Gaslini, UO Ostetr & Ginecol, Genoa, Italy Univ Genoa Genoa Italy nnina Gaslini, UO Ostetr & Ginecol, Genoa, Italy
Titolo Testata:
ULTRASOUND IN OBSTETRICS & GYNECOLOGY
fascicolo: 4, volume: 17, anno: 2001,
pagine: 301 - 305
SICI:
0960-7692(200104)17:4<301:RODVDF>2.0.ZU;2-B
Fonte:
ISI
Lingua:
ENG
Soggetto:
VELOCITY WAVE-FORMS; BLOOD-FLOW; NUCHAL TRANSLUCENCY; FETAL CIRCULATION; FIRST-TRIMESTER; FETUSES; PREGNANCY; ARTERIAL; RELIABILITY; AGREEMENT;
Keywords:
ductus venosus; Doppler; intraobserver repeatability; interobserver repeatability; intraclass correlation coefficient;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Citazioni:
23
Recensione:
Indirizzi per estratti:
Indirizzo: Prefumo, F Piazza Martiri della Liberta 2-5, I-17100 Savona, Italy PiazzaMartiri della Liberta 2-5 Savona Italy I-17100 , Italy
Citazione:
F. Prefumo et al., "Reproducibility of ductus venosus Doppler flow measurements at 11-14 weeksof gestation", ULTRASOUN O, 17(4), 2001, pp. 301-305

Abstract

Objectives To assess the intra- and interobserver repeatabilities of fetalductus venosus Doppler measurements at 11-14 weeks of gestation. Design Flow velocity waveforms were recorded transabdominally. Intraobserver repeatability was studied in 22 fetuses in whom four repeated measurements were performed by the same observer. Interobserver repeatability was assessed in 54 fetuses in each of whom two observers performed two repeated measurements. The pulsatility index for veins (PIV), peak velocity during ventricular systole (S wave), peak velocity during atrial contraction (A wave)and time-averaged maximum velocity (TAMV) were recorded. Reproducibility of the Doppler measurements was analyzed by calculating repeatability coefficient, coefficient of variation (CV), intraclass correlation coefficient (ICC), mean differences and their limits of agreement. Cohen's k-coefficient was used for categorical data. Results Intraobserver repeatability was good with a CV of 10%, 13%, 22% and 13% and an ICC of 0.85, 0.94, 0.94 and 0.95, respectively, for PIV S wave, A wave and TAMV. Interobserver repeatability was also good, and no bias between the observers was detected. A CV of 8.8%, 14%, 27% and 15% and an ICC of 0.86, 0.84, 0.87 and 0.84, respectively, for PIV, S wave, A wave and TAMV were obtained. There was 100% agreement for the detection of normal/abnormal blood flow. Conclusions Intra- and interobserver repeatability of all parameters was acceptable, allowing for the detection of moderate to large changes in Doppler measurements.