Dilatation of stent-grafts by luminal pressures: experimental evaluation of polytetrafluoroethylene (PTFE) and woven polyester grafts
Autore:
Suzuki, K; Ishiguchi, T; Kawatsu, S; Iwai, H; Maruyama, K; Ishigaki, T;
Indirizzi:
Nagoya Univ, Sch Med, Dept Radiol, Showa Ku, Nagoya, Aichi 4668550, Japan Nagoya Univ Nagoya Aichi Japan 4668550 a Ku, Nagoya, Aichi 4668550, Japan
Titolo Testata:
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY
fascicolo: 2, volume: 24, anno: 2001,
pagine: 94 - 98
SICI:
0174-1551(200103/04)24:2<94:DOSBLP>2.0.ZU;2-3
Fonte:
ISI
Lingua:
ENG
Soggetto:
ABDOMINAL AORTIC-ANEURYSMS; EXPANDED POLYTETRAFLUOROETHYLENE; FEMOROPOPLITEAL BYPASS; AORTOILIAC ANEURYSMS; DACRON GRAFTS; PLACEMENT;
Keywords:
stent-graft, dilatation; polytetrafluoroethylene; woven polyester; aortic aneurysm;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Citazioni:
21
Recensione:
Indirizzi per estratti:
Indirizzo: Suzuki, K Nagoya Univ, Sch Med, Dept Radiol, Showa Ku, 65 Tsurumai Cho, Nagoya, Aichi 4668550, Japan Nagoya Univ 65 Tsurumai Cho Nagoya Aichi Japan 4668550 50, Japan
Citazione:
K. Suzuki et al., "Dilatation of stent-grafts by luminal pressures: experimental evaluation of polytetrafluoroethylene (PTFE) and woven polyester grafts", CARDIO IN R, 24(2), 2001, pp. 94-98

Abstract

Purpose: To evaluate the effect on dilatation of three types of covering materials used for endovascular stent-grafts. Methods: Stent-grafts with three types of covering material [0.1-mm polytetrafluoroethylene (PTFE), 0.2-mm PTFE, and 0.15-mm woven polyester] were placed in a fluid circuit. For the pulsatile pressure test, the luminal pressure of 190/ 130 mmHg was loaded up to 300,000 pulses. For the static pressure test, the luminal pressure was increased from 50 to 300 mmHg at 50-mmHg increments. The percent of dilation of each stent-graft was compared. Results: The 0.1-mm PTFE stent-graft was significantly more dilated than the 0.2-mm PTFE and the 0.15-mm woven polyester stent-graft (p < 0.005) in both examinations. There was no significant difference between the 0.2-mm PTFE and the 0.15-mm woven polyester stent-grafts. The dilatation of the 0.1-mm PTFE stent-graft was irreversible. Conclusion: The 0.15-mm woven polyester and the 0.2-mm PTFE stent-grafts may be preferable to the 0.1-mm PTFE stent-graft with regard to dilatation and deformity.