Catalogo Articoli (Spogli Riviste)

OPAC HELP

Titolo:
Wireless ECG monitoring by telephone
Autore:
Orlov, OI; Drozdov, DV; Doarn, CR; Merrell, RC;
Indirizzi:
Virginia Commonwealth Univ, Med Informat & Technol Applicat Consortium, Richmond, VA 23298 USA Virginia Commonwealth Univ Richmond VA USA 23298 , Richmond, VA 23298 USA Space Biomed Ctr Training & Res, Moscow, Russia Space Biomed Ctr Training & Res Moscow Russia ing & Res, Moscow, Russia
Titolo Testata:
TELEMEDICINE JOURNAL AND E-HEALTH
fascicolo: 1, volume: 7, anno: 2001,
pagine: 33 - 38
SICI:
1530-5627(200121)7:1<33:WEMBT>2.0.ZU;2-R
Fonte:
ISI
Lingua:
ENG
Soggetto:
CARDIAC REHABILITATION; VOICE;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Citazioni:
7
Recensione:
Indirizzi per estratti:
Indirizzo: Doarn, CR Virginia Commonwealth Univ, Med Informat & Technol Applicat Consortium, POB 980480, Richmond, VA 23298 USA Virginia Commonwealth Univ POB 980480 Richmond VA USA 23298 USA
Citazione:
O.I. Orlov et al., "Wireless ECG monitoring by telephone", TELEMED J E, 7(1), 2001, pp. 33-38

Abstract

The objective of this work was to study a wireless one channel limited (3-lead) home electrocardiogram (ECG) transmission system and ambulatory devices data transmission using telephone lines. ECG screenings were conducted in two groups. The first group consisted of construction workers examined atfirst aid stations at construction sites in Moscow, Russia. The second group was a selected set of patients admitted to a hospital in Tblisi, Republic of Georgia. All patients were on constant monitoring and follow-up after hospitalization. Patients themselves connected the ECG leads at home or with the help of paramedics at ambulatory stations. The ECG signals were transmitted to receiving stations where doctors interpreted them. Frequency modulation was used for ECG transmission over regular telephone lines. Of 231 readings in 74 patients-70 male and 4 female (age 21-56)-in the first group,33 patients were abnormal. In the second group, 15 out of 165 readings in 8 patients-5 male and 3 female (age 31-70)-were abnormal. ECG screening canbe significantly simplified and made widely acceptable at home and distantsites using wireless monitoring tools and telephone line transfer of the signal. This project has been implemented under the auspices of the International Telecommunication Union and the Russian Telemedicine Foundation.

ASDD Area Sistemi Dipartimentali e Documentali, Università di Bologna, Catalogo delle riviste ed altri periodici
Documento generato il 05/04/20 alle ore 02:19:42