Catalogo Articoli (Spogli Riviste)

OPAC HELP

Titolo:
Knee laxity after ACL reconstruction with a BPTB graft
Autore:
Rupp, S; Muller, B; Seil, R;
Indirizzi:
Univ Saarlandes, Univ Hosp, Dept Orthopaed Surg, D-66421 Homburg, Germany Univ Saarlandes Homburg Germany D-66421 d Surg, D-66421 Homburg, Germany
Titolo Testata:
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY
fascicolo: 2, volume: 9, anno: 2001,
pagine: 72 - 76
SICI:
0942-2056(200103)9:2<72:KLAARW>2.0.ZU;2-E
Fonte:
ISI
Lingua:
ENG
Soggetto:
ANTERIOR CRUCIATE LIGAMENT; AUTOGENOUS PATELLAR TENDON; MECHANICAL-PROPERTIES; FOLLOW-UP; REPLACEMENT; 2-YEAR; AUTOGRAFTS; SHEEP; DOG;
Keywords:
anterior cruciate ligament; BPTB graft; surgery; follow-up; KT-1000;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Citazioni:
31
Recensione:
Indirizzi per estratti:
Indirizzo: Rupp, S Univ Saarlandes, Univ Hosp, Dept Orthopaed Surg, D-66421 Homburg, Germany Univ Saarlandes Homburg Germany D-66421 D-66421 Homburg, Germany
Citazione:
S. Rupp et al., "Knee laxity after ACL reconstruction with a BPTB graft", KNEE SURG S, 9(2), 2001, pp. 72-76

Abstract

The objective of the study was to compare prospectively shortterm and mid-term results after ACL reconstruction with special focus on changes in instrumented knee laxity. Methods: The original study group included prospectively 58 patients who underwent arthroscopically assisted ACL reconstruction with BPTB graft in a two-tunnel technique between 1991 and 1993. Seven patients were lost to follow-up, leaving 51 patients for a first follow-up at 6months and a second follow-up at 3-6 years (mean 4.3 years). Clinical results were evaluated by means of the Lysholm score and the IKDC score. Laxitywas assessed using a KT-1000 arthrometer applying an 89 N anterior load in20 degrees of flexion. Increased laxity was defined as a 3 mm increase in AP translation between the first and the second follow-up. Results: At mid-term follow-up pivot shift was negative in 86% of cases. IKDC score: normal=28%, nearly normal=44%, abnormal=24%, severely abnormal=4%. KT-1000: <3 mm=68%, 3-5 mm=24%,>5 mm=8%. The mean KT-1000 side-to-side difference was 1.08 (0.17) mm at 6 months and 2.01 (0.29) mm at 3-6 years. The difference wasstatistically significant (P <0.005). According to the defined criteria, seven patients had increased laxity at the second follow-up, suggesting a malfunction of the graft due to stretch-out or injury. In this subgroup the mean KT-1000 measurements were 0.86 (0.26) mm at the first follow-up and 5.93 (0.54) mm at the second follow-up. In five of these patients, a malposition of the tunnels was identified as a possible cause. In the remaining group, KT-1000 measurements did not differ significantly between the first and the second follow-up [1.12(0.20) mm versus 1.37 (0.21) mm]. Conclusions: Increase in AP laxity occurred in 14% of our cases between the first and the second follow-up. In most of these cases increased laxity was due to inadequate surgical technique, especially malposition of bony tunnels. If tunnel position was correct, there was no evidence for elongation of grafts over time as a general principle.

ASDD Area Sistemi Dipartimentali e Documentali, Università di Bologna, Catalogo delle riviste ed altri periodici
Documento generato il 05/04/20 alle ore 06:51:54