Catalogo Articoli (Spogli Riviste)

OPAC HELP

Titolo:
Teletransmission system supporting intensive insulin treatment of out-clinic type 1 diabetic pregnant women. Technical assessment during 3 years' application
Autore:
Ladyzynski, P; Wojcicki, JM; Krzymien, J; Blachowicz, J; Jozwicka, E; Czajkowski, K; Janczewska, E; Karnafel, W;
Indirizzi:
PAS, Inst Biocybernet & Biomed Engn, PL-02109 Warsaw, Poland PAS Warsaw Poland PL-02109 bernet & Biomed Engn, PL-02109 Warsaw, Poland Dept & Clin Gastroenterol & Metab Dis MA, Warsaw, Poland Dept & Clin Gastroenterol & Metab Dis MA Warsaw Poland , Warsaw, Poland Dept Obstet & Gynecol 2, Warsaw, Poland Dept Obstet & Gynecol 2 Warsaw Poland bstet & Gynecol 2, Warsaw, Poland Dept Obstet & Gynecol 1, Warsaw, Poland Dept Obstet & Gynecol 1 Warsaw Poland bstet & Gynecol 1, Warsaw, Poland Clin Obstet & Gynaecol MA, Warsaw, Poland Clin Obstet & Gynaecol MA Warsaw Poland t & Gynaecol MA, Warsaw, Poland
Titolo Testata:
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS
fascicolo: 3, volume: 24, anno: 2001,
pagine: 157 - 163
SICI:
0391-3988(200103)24:3<157:TSSIIT>2.0.ZU;2-E
Fonte:
ISI
Lingua:
ENG
Soggetto:
BLOOD-GLUCOSE; RELIABILITY;
Keywords:
telemedicine; diabetes mellitus; telemonitoring; telecare; computer systems; pregnancy;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Citazioni:
16
Recensione:
Indirizzi per estratti:
Indirizzo: Ladyzynski, P PAS, Inst Biocybernet & Biomed Engn, Trojdena 4, PL-02109 Warsaw, Poland PAS Trojdena 4 Warsaw Poland PL-02109 -02109 Warsaw, Poland
Citazione:
P. Ladyzynski et al., "Teletransmission system supporting intensive insulin treatment of out-clinic type 1 diabetic pregnant women. Technical assessment during 3 years' application", INT J ARTIF, 24(3), 2001, pp. 157-163

Abstract

A telematic system supporting intensive insulin treatment of pregnant typeI diabetic out-clinic patients was implemented and technical efficiency ofthe system was evaluated over longterm ambulatory application. The system consists of a patient teletransmission module (PTM) and a central clinical control unit (CCU). The PTM contains a one-box blood glucose meter and electronic logbook, a modem and a dial-up or cellular phone set The CCU consists of a PC computer with a modem and DIAPRET - an original program designed to monitor the intensive insulin treatment The system was installed in the Clinic of Gastroenterology and Metabolic Disease, MA Warsaw and was tested for 166 +/- 24 days on 15 pregnant type 1 diabetic women. Telemonitoring ofthe patient data was done automatically. No major technical problems with proper operation or handling of the system was noted. Total effectiveness was 69.3 +/- 13.0% and technical effectiveness 91.5 +/- 6.1%. The efficacy of the system was not significantly influenced by patient intelligence level, education level or place of residence (p < 0.05). Significant improvementof metabolic control was noted during application of the system. In conclusion, the telematic system we developed and implemented should have a positive influence on the qualify of diabetes treatment during pregnancy.

ASDD Area Sistemi Dipartimentali e Documentali, Università di Bologna, Catalogo delle riviste ed altri periodici
Documento generato il 30/05/20 alle ore 15:19:14