Reducing oblique flow effects in interleaved EPI with a centric reorderingtechnique
Autore:
Beck, G; Li, D; Haacke, EM; Noll, TG; Schad, LR;
Indirizzi:
Philips Med Syst BV, Best, Netherlands Philips Med Syst BV Best Netherlands ips Med Syst BV, Best, Netherlands Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA Northwestern Univ Chicago IL USA 60611 Dept Radiol, Chicago, IL 60611 USA Magnet Resonance Imaging Inst Biomed Res, St Louis, MO USA Magnet Resonance Imaging Inst Biomed Res St Louis MO USA t Louis, MO USA Aachen Univ Technol, Dept Elect & Comp Syst Engn, Aachen, Germany Aachen Univ Technol Aachen Germany ct & Comp Syst Engn, Aachen, Germany German Canc Res Ctr, D-6900 Heidelberg, Germany German Canc Res Ctr Heidelberg Germany D-6900 D-6900 Heidelberg, Germany
Titolo Testata:
MAGNETIC RESONANCE IN MEDICINE
fascicolo: 4, volume: 45, anno: 2001,
pagine: 623 - 629
SICI:
0740-3194(200104)45:4<623:ROFEII>2.0.ZU;2-E
Fonte:
ISI
Lingua:
ENG
Soggetto:
ECHO-PLANAR; MOTION SENSITIVITY; ARTIFACTS; COMPENSATION;
Keywords:
magnetic resonance imaging; fast MRI; echo planar imaging; segmented data acquisition; interleaved; MR angiography; flow artifacts;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Life Sciences
Citazioni:
18
Recensione:
Indirizzi per estratti:
Indirizzo: Beck, G Ds de Jonglaan 36, NL-5913 RL Venlo, Netherlands Ds de Jonglaan 36 Venlo Netherlands NL-5913 RL enlo, Netherlands
Citazione:
G. Beck et al., "Reducing oblique flow effects in interleaved EPI with a centric reorderingtechnique", MAGN RES M, 45(4), 2001, pp. 623-629

Abstract

Segmented interleaved echo planar imaging offers a fast and efficient approach to magnetic resonance angiography, Unfortunately, this technique Is particularly sensitive to oblique flow in the imaging plane, In this work, a mathematical analysis of oblique flow effects for several types of k-space coverage is presented, The conventional linear acquisition scheme, an alternating centric and a nonalternating centric encoding scheme are compared with respect to their flow properties. It is shown both by simulations and imaging experiments that artifacts from oblique in-plane flow are effectivelyreduced by both centric reordered phase-encoding schemes, The nonalternating centric acquisition scheme is preferred to the alternating centric scheme due to the smoother phase error transition in k-space in the presence of obliquely-angled flow, Magn Reson Med 45:623-629, 2001, (C) 2001 Wiley-Liss, Inc.