Reliability of manometric eustachian tube function tests in children
Autore:
van Heerbeek, N; Ingels, KJAO; Snik, AFM; Zielhuis, GA;
Indirizzi:
Univ Nijmegen, Med Ctr St Radboud, Dept Otorhinolaryngol, NL-6500 HB Nijmegen, Netherlands Univ Nijmegen Nijmegen Netherlands NL-6500 HB 0 HB Nijmegen, Netherlands Univ Nijmegen, Med Ctr St Radboud, Dept Epidemiol, NL-6500 HB Nijmegen, Netherlands Univ Nijmegen Nijmegen Netherlands NL-6500 HB 0 HB Nijmegen, Netherlands
Titolo Testata:
OTOLOGY & NEUROTOLOGY
fascicolo: 2, volume: 22, anno: 2001,
pagine: 183 - 187
SICI:
1531-7129(200103)22:2<183:ROMETF>2.0.ZU;2-D
Fonte:
ISI
Lingua:
ENG
Soggetto:
SECRETORY OTITIS-MEDIA; NORMAL EARS; MIDDLE-EAR; EFFUSION; MANAGEMENT; SINUSITIS; ADULTS;
Keywords:
eustachian tube function; reliability; otitis; media with effusion;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Citazioni:
26
Recensione:
Indirizzi per estratti:
Indirizzo: van Heerbeek, N Univ Nijmegen, Med Ctr St Radboud, Dept Otorhinolaryngol, POB 9101, NL-6500 HB Nijmegen, Netherlands Univ Nijmegen POB 9101 NijmegenNetherlands NL-6500 HB ds
Citazione:
N. van Heerbeek et al., "Reliability of manometric eustachian tube function tests in children", OTOL NEURO, 22(2), 2001, pp. 183-187

Abstract

Objective: To assess the reliability of manometric eustachian tube function tests in children with ventilation tubes in situ. Study Design: Repeated manometric eustachian tube function tests during one session. Setting: The study took place at a secondary referral hospital and a tertiary referral hospital. Patients: Ninety-nine children with ventilation tubes in situ because of persistent otitis media with effusion. Main Outcome Measures: Opening pressure (Po), closing pressure (Pc), and tubal function group. Results: Analysis of Po and Pc showed a decrease with repeated measurement(p = 0.0001 and p = 0.001, respectively). The effect of repeated measurement on Po was more pronounced than the effect on Pc. The results of the first and second pressure equilibration tests showed 99% agreement. Conclusions: This study showed good reproducibility of the categorized results of the pressure equilibration test, whereas the results of the forced-response test seemed to be less reproducible and showed a downward shift with repeated measurement. A single measurement using wet swallowing and starting pressures of 100 and -100 daPa and the mean of the first three measurements of the Po and Pc are sufficient to determine tubal function. Further studies are needed to determine the discriminative power of these tests in children with different degrees of middle ear disease.