Catalogo Articoli (Spogli Riviste)

OPAC HELP

Titolo:
Ergometry for estimation of mechanical power output in sprinting in humansusing a newly developed self-driven treadmill
Autore:
Funato, K; Yanagiya, T; Fukunaga, T;
Indirizzi:
Japan Inst Sports Sci, Dept Sports Sci, Kita Ku, Tokyo 1150056, Japan Japan Inst Sports Sci Tokyo Japan 1150056 Kita Ku, Tokyo 1150056, Japan Univ Tokyo, Dept Life Sci Sports Sci, Tokyo 1538902, Japan Univ Tokyo Tokyo Japan 1538902 Life Sci Sports Sci, Tokyo 1538902, Japan
Titolo Testata:
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY
fascicolo: 3, volume: 84, anno: 2001,
pagine: 169 - 173
SICI:
1439-6319(200103)84:3<169:EFEOMP>2.0.ZU;2-7
Fonte:
ISI
Lingua:
ENG
Keywords:
mechanical power; walking; running; sprinting; ergometer;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Life Sciences
Citazioni:
8
Recensione:
Indirizzi per estratti:
Indirizzo: Funato, K Japan Inst Sports Sci, Dept Sports Sci, Kita Ku, 3-15-1 Nishigaoka, Tokyo 1150056, Japan Japan Inst Sports Sci 3-15-1 Nishigaoka Tokyo Japan 1150056 pan
Citazione:
K. Funato et al., "Ergometry for estimation of mechanical power output in sprinting in humansusing a newly developed self-driven treadmill", EUR J A PHY, 84(3), 2001, pp. 169-173

Abstract

An evaluation of mechanical power during walking and running in humans wasundertaken after developing a specially designed running ergometer (RE) inwhich the subjects gripped the handlebar in front of them keeping both arms straight and in a horizontal position. Ten subjects participated in comparisons of the mean horizontal pushing force (MFam) on the handlebar with the mean horizontal ground reaction force (MFfp) recorded by force platform under the RE during five different constant speeds of walking or running andsprint running with maximal effort. Mechanical power developed during sprint running on the RE was compared with a 50 m sprint. Mean linear velocity (M nu) of the RE belt was recorded by the rotary encoder attached to the axis of the belt. Mean mechanical power calculated from the handlebar setting(MPam = MFam x M nu) was compared to that calculated from force platform recordings (MPfp = MFfp x M nu). A high test-retest reproducibility was observed for both MFfp (r = 0.889) and MFam (r = 0.783). Larger values for the coefficient of variation for MFam (11.3%-15.8%) were observed than for MFfp(3.3%-8.2%). The MPam, which were obtained from five different constant speeds of walking, running and sprint running were closely correlated to those of MPfp (y = 0.98x - 19.10, r = 0.982, P < 0.001). In sprint running, MPam was 521.7 W (7.67 W (.) kg(-1)) and was correlated to the 50 m sprint time (r = -0.683, P < 0.01). It is concluded that the newly developed RE was useful in the estimation of mechanical power output during human locomotion such as when walking, jogging and sprinting.

ASDD Area Sistemi Dipartimentali e Documentali, Università di Bologna, Catalogo delle riviste ed altri periodici
Documento generato il 04/04/20 alle ore 08:49:34