Catalogo Articoli (Spogli Riviste)

OPAC HELP

Titolo:
Analytical applications of flow injection with chemiluminescence detection- a review
Autore:
Fletcher, P; Andrew, KN; Calokerinos, AC; Forbes, S; Worsfold, PJ;
Indirizzi:
Univ Plymouth, Plymouth Environm Res Ctr, Dept Environm Sci, Plymouth PL4 8AA, Devon, England Univ Plymouth Plymouth Devon England PL4 8AA outh PL4 8AA, Devon, England Univ Athens, Analyt Chem Lab, Dept Chem, Athens 15771, Greece Univ AthensAthens Greece 15771 hem Lab, Dept Chem, Athens 15771, Greece Shell Global Solut, Analyt Technol Business Grp, Chester CH1 3SH, Cheshire, England Shell Global Solut Chester Cheshire England CH1 3SH SH, Cheshire, England
Titolo Testata:
LUMINESCENCE
fascicolo: 1, volume: 16, anno: 2001,
pagine: 1 - 23
SICI:
1522-7235(200101/02)16:1<1:AAOFIW>2.0.ZU;2-W
Fonte:
ISI
Lingua:
ENG
Soggetto:
DEHYDROGENASE NADH OXIDASE; SYSTEM LUMINOL-H2O2-FE(CN)(6)(3-) CHEMILUMINESCENCE; ENHANCED LUMINOL CHEMILUMINESCENCE; IMMOBILIZED ENZYME REACTORS; RED TIDE PHYTOPLANKTON; HYDROGEN-PEROXIDE; PEROXYOXALATE CHEMILUMINESCENCE; ELECTROGENERATED HYPOCHLORITE; ASCORBIC-ACID; AMINO-ACIDS;
Keywords:
flow injection; chemiluminescence; pharmaceutical; environmental; foods and beverages; biomedical;
Tipo documento:
Review
Natura:
Periodico
Settore Disciplinare:
Life Sciences
Citazioni:
238
Recensione:
Indirizzi per estratti:
Indirizzo: Worsfold, PJ Univ Plymouth, Plymouth Environm Res Ctr, Dept Environm Sci, Drake Circus,Plymouth PL4 8AA, Devon, England Univ Plymouth Drake Circus Plymouth Devon England PL4 8AA and
Citazione:
P. Fletcher et al., "Analytical applications of flow injection with chemiluminescence detection- a review", LUMINESCENC, 16(1), 2001, pp. 1-23

Abstract

This paper reviews the literature on analytical applications of flow injection (FI) techniques with chemiluminescence (CL) detection from 1995-1999. The focus is on the application of FI-CL to the quantitative determination of specific analytes in real sample matrices. Therefore, entries have been tabulated under the most appropriate application area, ie pharmaceutical, environmental, foods and beverages and biomedical, as defined by the matrix that has been analysed. Each table lists analytes alphabetically and gives details of the exact sample matrix, the limit of detection (as reported in the original paper) and comments on the CL reaction used. Copyright (C) 2001 John Wiley & Sons, Ltd.

ASDD Area Sistemi Dipartimentali e Documentali, Università di Bologna, Catalogo delle riviste ed altri periodici
Documento generato il 31/03/20 alle ore 16:02:31