Catalogo Articoli (Spogli Riviste)

OPAC HELP

Titolo:
A comparison of iterative minimum norm estimation and current dipole estimation for magnetic field measurements from small animals
Autore:
Uchida, S; Iramina, K; Goto, K; Ueno, S;
Indirizzi:
Univ Tokyo, Grad Sch Med, Dept Biomed Engn, Bunkyo Ku, Tokyo 1130033, Japan Univ Tokyo Tokyo Japan 1130033 med Engn, Bunkyo Ku, Tokyo 1130033, Japan
Titolo Testata:
IEEE TRANSACTIONS ON MAGNETICS
fascicolo: 5, volume: 36, anno: 2000,
parte:, 1
pagine: 3724 - 3726
SICI:
0018-9464(200009)36:5<3724:ACOIMN>2.0.ZU;2-H
Fonte:
ISI
Lingua:
ENG
Keywords:
auditory evoked magnetic fields; high resolution dc-SQUID; magnetoencephalography; minimum norm estimation; rats; source localization;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Physical, Chemical & Earth Sciences
Citazioni:
4
Recensione:
Indirizzi per estratti:
Indirizzo: Uchida, S Univ Tokyo, Grad Sch Med, Dept Biomed Engn, Bunkyo Ku, 7-3-1 HOngo, Tokyo 1130033, Japan Univ Tokyo 7-3-1 HOngo Tokyo Japan 1130033 Tokyo 1130033, Japan
Citazione:
S. Uchida et al., "A comparison of iterative minimum norm estimation and current dipole estimation for magnetic field measurements from small animals", IEEE MAGNET, 36(5), 2000, pp. 3724-3726

Abstract

We developed a multi-channel high-resolution SQUID magnetometer for measuring biomagnetic fields produced by small animals, The diameter of the pickup coils in our system is 5 mm, i.e., smaller than typical systems. 12 magnetic fields on a 7.5 mm grid were measured with better spatial resolution than typical systems, We measured the magnetic field response to auditory stimuli in rat brains in a magnetically shielded room. Eight male rats were anesthetized intraperitoneally with Urethane (1 g/1 kg) and stimuli consisting of 3 Hz tone burst sounds were introduced to the left ears. Averaging of the magnetic fields was performed for over 3000 auditory stimuli. The localization of current sources was calculated by two methods, the iterative minimum norm estimation (MNE) and the current dipole model (CDM), Current sources were localized in the auditory area of the right hemisphere in the rat's cortex by iterative MNE, Estimated sources by CDM were localized more deeply than estimated current sources by iterative MNE, The correlation coefficient between the measured magnetic fields and the reconstructed magnetic fields in current sources was higher for iterative MNE than CDM, Iterative MNE is useful for source localization of auditory cortical activities in rats, Our system is a useful and noninvasive tool for brain research in small animals.

ASDD Area Sistemi Dipartimentali e Documentali, Università di Bologna, Catalogo delle riviste ed altri periodici
Documento generato il 25/01/20 alle ore 00:30:50