Cut-off point, timing and pitfalls of the C-13-urea breath test as measured by infrared spectrometry
Autore:
Mana, F; Franken, PR; Ham, HR; Urbain, D;
Indirizzi:
Free Univ Brussels, Acad Hosp, Dept Gastroenterol, Jette, Belgium Free Univ Brussels Jette Belgium sp, Dept Gastroenterol, Jette, Belgium St Pieter Hosp, Dept Nucl Med, Brussels, Belgium St Pieter Hosp BrusselsBelgium Hosp, Dept Nucl Med, Brussels, Belgium
Titolo Testata:
DIGESTIVE AND LIVER DISEASE
fascicolo: 1, volume: 33, anno: 2001,
pagine: 30 - 35
SICI:
1590-8658(200101/02)33:1<30:CPTAPO>2.0.ZU;2-I
Fonte:
ISI
Lingua:
ENG
Soggetto:
HELICOBACTER-PYLORI INFECTION; HEILMANNII FORMERLY GASTROSPIRILLUM; GASTRIC LYMPHOMA; MALT LYMPHOMA; HOMINIS; SPECTROSCOPY; ERADICATION; ASSOCIATION; REGRESSION; OMEPRAZOLE;
Keywords:
Helicobacter pylori; UBT;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Citazioni:
29
Recensione:
Indirizzi per estratti:
Indirizzo: Mana, F Free Univ Brussels, Dept Gastroenterol, Laarbeeklaan 101, B-1090 Brussels,Belgium Free Univ Brussels Laarbeeklaan 101 Brussels Belgium B-1090 lgium
Citazione:
F. Mana et al., "Cut-off point, timing and pitfalls of the C-13-urea breath test as measured by infrared spectrometry", DIG LIVER D, 33(1), 2001, pp. 30-35

Abstract

Background. The best timing and the best cut-off level of the C-13-urea breath test have not yet been well established. Aims. To evaluate the cut-off value and the influence of medication on theC-13-urea breath test as measured by infrared spectrometry. Methods. A series of 223 patients, sent for endoscopy, performed C-13-ureabreath test in fasting conditions with 75 mg of C-13-urea and 20 mi of citric acid. Breath samples were collected before and then 10, 20, 25 and 30 minutes after ingestion. As gold standard, histological examination of gastric biopsies was used. A questionnaire was completed concerning the intake of medication, likely to influence the test, in the 2 months preceding the test. Sensitivity, specificity, positive predictive value and negative predictive value at 10 20, 25 and 30 minutes at different cut-off values (3, 3.5, 4, 4.5, 5.00/00 DOB) were calculated. Results. A total of 182 patients did not take medication. There was no significant difference between the different cut-off levels at different times. Compared with the group of 41 patients who did take medication, likely toinfluence the test, the differences were significant (Fisher exact test)Conclusion. There was no significant difference between the different cut-off values. A 10-minute test with a cut-off level between 4 and 5% delta over baseline (sensitivity: 100%, specificity: 95%) is, therefore, proposed. To avoid false negative results due to unknown intake of medication, every patient submitted to the C-13-urea breath test should fill out a questionnaire.