Comparison of myocardial fractional flow reserve and intravascular ultrasound for the assessment of slotted-tube stents
Autore:
Katritsis, DG; Ioannidis, JPA; Korovesis, S; Giazitzoglou, E; Parissis, J; Kalivas, P; Webb-Peploe, MM;
Indirizzi:
Athens Euroclin, Dept Cardiol, Athens 11521, Greece Athens Euroclin Athens Greece 11521 , Dept Cardiol, Athens 11521, Greece St Thomas Hosp, Ctr Cardiothorac, London, England St Thomas Hosp London England s Hosp, Ctr Cardiothorac, London, England Univ Ioannina, Sch Med, Dept Hyg & Epidemiol, Clin & Mol Epidemiol Unit, GR-45110 Ioannina, Greece Univ Ioannina Ioannina Greece GR-45110 l Unit, GR-45110 Ioannina, Greece Tufts Univ, Sch Med, Dept Med, Boston, MA 02111 USA Tufts Univ Boston MA USA 02111 v, Sch Med, Dept Med, Boston, MA 02111 USA
Titolo Testata:
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS
fascicolo: 3, volume: 52, anno: 2001,
pagine: 322 - 326
SICI:
1522-1946(200103)52:3<322:COMFFR>2.0.ZU;2-F
Fonte:
ISI
Lingua:
ENG
Soggetto:
QUANTITATIVE CORONARY ANGIOGRAPHY; INTRACORONARY ULTRASOUND; PRESSURE; STENOSIS;
Keywords:
fractional flow reserve; coronary angioplasty; stenting;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Citazioni:
11
Recensione:
Indirizzi per estratti:
Indirizzo: Katritsis, DG Athens Euroclin, Dept Cardiol, 9 Athanassiadou St, Athens 11521, Greece Athens Euroclin 9 Athanassiadou St Athens Greece 11521 eece
Citazione:
D.G. Katritsis et al., "Comparison of myocardial fractional flow reserve and intravascular ultrasound for the assessment of slotted-tube stents", CATHET C IN, 52(3), 2001, pp. 322-326

Abstract

Intravascular ultrasound (IVUS) and myocardial fractional flow reserve (FFR) have been reported to provide similar results for assessment of coil stent deployment Their relative value in slotted-tube stents has not been investigated. Fourteen patients subjected to coronary angioplasty and IVUS-guided elective stenting with a slotted-tube stent underwent IVUS assessment and FFR measurement following stent implantation at inflation pressures of 12and 18 atm. FFR values (mean +/- SD) preangioplasty, postangioplasty, and poststenting at 12 atm and 18 atm, were 0.58 +/- 0.07, 0.83 +/- 0.05, 0.94 /- 0.02, and 0.94 +/- 0.02, respectively. After inflation at 12 atm, the area under the receiver operating characteristic (ROC) curve for the concordance of IVUS and FFR measurements was 0.89 (P = 0.02), Six patients had either an abnormal IVUS (n = 2) or FFR < 0.94 (n = 1) or both abnormal IVUS and FFR < 0.94 (n = 3) after the first inflation and had a second inflation at 18 atm. The area under the ROC curve for the concordance between IVUS andFFR final measurements was 0.855 (P = 0.10). Perfect concordance between IVUS and FFR was seen only for FFR values less than 0.91 or larger than 0.94. Overall, IVUS and FFR have substantial concordance with respect to slotted-tube stent deployment. However, FFR values between 0.91 and 0.94 after inflation are difficult to interpret. (C) 2001 Wiley-Liss, Inc.