Clinical experience of cerebral protection with balloon occlusion during carotid artery stenting.
Autore:
Jager, HJ; Mathias, KD; Drescher, R; Bockisch, G; Hauth, E; Demirel, E; Gissler, HM;
Indirizzi:
Stadt Kliniken Dortmund, Radiol Klin, D-44139 Dortmund, Germany Stadt Kliniken Dortmund Dortmund Germany D-44139 44139 Dortmund, Germany Univ Witten Herdecke, Lehrstuhl Radiol & Mikrotherapie, Witten, Germany Univ Witten Herdecke Witten Germany ol & Mikrotherapie, Witten, Germany
Titolo Testata:
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN
fascicolo: 2, volume: 173, anno: 2001,
pagine: 139 - 146
SICI:
1438-9029(200102)173:2<139:CEOCPW>2.0.ZU;2-B
Fonte:
ISI
Lingua:
GER
Soggetto:
DIFFUSION-WEIGHTED MR; ACUTE STROKE; ANGIOPLASTY; PLACEMENT; STENOSIS; ENDARTERECTOMY; ABNORMALITIES; INFARCTION; IMAGES;
Keywords:
carotid arteries, stenosis or obstruction; carotid arteries, transluminal angioplasty; cerebral protection;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Citazioni:
24
Recensione:
Indirizzi per estratti:
Indirizzo: Jager, HJ Stadt Kliniken Dortmund, Radiol Klin, Beurhausstr 40, D-44139 Dortmund, Germany Stadt Kliniken Dortmund Beurhausstr 40 Dortmund Germany D-44139
Citazione:
H.J. Jager et al., "Clinical experience of cerebral protection with balloon occlusion during carotid artery stenting.", ROFO-F RONT, 173(2), 2001, pp. 139-146

Abstract

Purpose: To assess the technical feasibility and the results of cerebral protection with the GuardWire Plus Temporary Occlusion & Aspiration System during carotid artery stenting for high-grade stenosis. Patients and Methods: In 20 patients 20 carotid artery stenoses were treated with stent placement under cerebral protection. A contralateral carotid occlusion was an exclusion criteria for the use of the protection device. In all cases only aspiration, but no flushing was used before deflation of the occlusion balloon. In 17 of 20 patients diffusion-weighted (DW-)MRT imaging of the brain was performed before and 24 hours after the procedure. Results: The stent implantation was successfully performed in all patients. in 3 patients neurologic symptoms occurred during the occlusion time. In these 3 patients the symptoms immediately disappeared after deflation of the balloon. In one case there was dilatation of the internal carotid artery at the site of the balloon inflation. In 3 of the 17 DW-MR images new ipsilateral cerebral lesions, in one case a new contralateral lesion occurred after the procedure. Conclusions: The cerebral protection procedure is technically feasible. The occlusion of the internal carotid artery was not tolerated by all patients. The DW-MR imaging demonstrated cerebral lesions indicating the occurrence of cerebral microemboli during the procedure. Further investigations are necessary to determine if the use of the cerebral protection device will improve the results of the carotid artery stenting for high-grade stenoses.