The standardization of Lu-177 by 4 pi ss liquid scintillation spectrometrywith H-3-standard efficiency tracing
Autore:
Zimmerman, BE; Unterweger, MP; Brodack, JW;
Indirizzi:
Natl Inst Stand & Technol, Phys Lab, Gaithersburg, MD 20899 USA Natl Inst Stand & Technol Gaithersburg MD USA 20899 ersburg, MD 20899 USA Mallinckrodt Inc, Nucl Med R&D, St Louis, MO 63134 USA Mallinckrodt Inc St Louis MO USA 63134 cl Med R&D, St Louis, MO 63134 USA
Titolo Testata:
APPLIED RADIATION AND ISOTOPES
fascicolo: 4, volume: 54, anno: 2001,
pagine: 623 - 631
SICI:
0969-8043(200104)54:4<623:TSOLB4>2.0.ZU;2-L
Fonte:
ISI
Lingua:
ENG
Soggetto:
INTRAPERITONEAL RADIOIMMUNOTHERAPY; OVARIAN-CANCER;
Keywords:
efficiency tracing; liquid scintillation counting; lutetium-177; standardization;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Physical, Chemical & Earth Sciences
Citazioni:
14
Recensione:
Indirizzi per estratti:
Indirizzo: Zimmerman, BE Natl Inst Stand & Technol, Phys Lab, 100 Bur Dr, Gaithersburg, MD 20899 USA Natl Inst Stand & Technol 100 Bur Dr Gaithersburg MD USA 20899
Citazione:
B.E. Zimmerman et al., "The standardization of Lu-177 by 4 pi ss liquid scintillation spectrometrywith H-3-standard efficiency tracing", APPL RAD IS, 54(4), 2001, pp. 623-631

Abstract

Solutions containing the potential radiotherapy radionuclide Lu-177 have been standardized at the National Institute of Standards and Technology (NIST) by 4 pi beta liquid scintillation (LS) counting with H-3-standard efficiency tracing using the CIEMAT/NIST method. Confirmatory measurements were made with 4 pi NaI(Tl) gamma -ray spectrometry. Activity determinations weremade on 4 solutions over the course of 10 months with an expanded (k = 2) uncertainty on the activity of 0.8%. Half-life measurements were carried out using the NIST "4 pi" gamma ionization chamber (IC) and LS counting and gave a new value of 6.65 +/- 0.01d, which is shorter than the current ENSDF-recommended value bq 1.3%. Impurity analyses were performed by high-purity germanium (HPGe) gamma -ray spectrometry and indicated only the presence ofLu-177m at a level of 0.02% that of the Lu-177 as of the respective reference times: for the four solutions. Calibration factors fur the NIST IC and Vinten 671 ionization chambers were developed, as were dial settings for the NIST-maintained Capintec CRC-12, Published by Elsevier Science Ltd.