Simultaneous determination of silicic acid, Ca, Mg and Al in mineral waterand composite tablets by ion chromatography
Autore:
Xu, Q; Xu, C; Zhang, W; Wang, YP; Jin, LT; Haraguchi, H; Itoh, A; Tanaka, K;
Indirizzi:
E China Normal Univ, Dept Chem, Shanghai 200062, Peoples R China E China Normal Univ Shanghai Peoples R China 200062 062, Peoples R China Nagoya Univ, Sch Engn, Dept Appl Chem, Chikusa Ku, Nagoya, Aichi 4648603, Japan Nagoya Univ Nagoya Aichi Japan 4648603 a Ku, Nagoya, Aichi 4648603, Japan Natl Ind Res Inst Nagoya, Kita Ku, Nagoya, Aichi 462, Japan Natl Ind Res Inst Nagoya Nagoya Aichi Japan 462 Nagoya, Aichi 462, Japan
Titolo Testata:
CHROMATOGRAPHIA
fascicolo: 1-2, volume: 53, anno: 2001,
pagine: 81 - 84
SICI:
0009-5893(200101)53:1-2<81:SDOSAC>2.0.ZU;2-R
Fonte:
ISI
Lingua:
ENG
Soggetto:
EXCLUSION CHROMATOGRAPHY; INORGANIC ANIONS; ELUENT;
Keywords:
ion chromatography; simultaneous determination; conductometric detection; silicic acid, calcium, magnesium and aluminum;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Life Sciences
Physical, Chemical & Earth Sciences
Citazioni:
13
Recensione:
Indirizzi per estratti:
Indirizzo: Jin, LT E China Normal Univ, Dept Chem, Shanghai 200062, Peoples R China EChina Normal Univ Shanghai Peoples R China 200062 ples R China
Citazione:
Q. Xu et al., "Simultaneous determination of silicic acid, Ca, Mg and Al in mineral waterand composite tablets by ion chromatography", CHROMATOGR, 53(1-2), 2001, pp. 81-84

Abstract

A simple, selective and sensitive ion-chromatography method was investigated for simultaneously determining silicic acid, Ca2+, Mg2+, Al3+ and anions(Cl- and NO3-) in real samples. it involved a single-column ion-chromatograph with sodium hydroxide-methanol-water eluent and conductometric detection. Cations were converted to complex onions ky adding EDTA to the sample solution. A set of well-defined peaks of silicic acid, Ca2+, Mg2+, Al3+, Cl- and NO3- were obtained. Detection limits using 3.3 sigma (sigma = standard deviation of blank solution) were 1.25 x 10(-6) M for H3SiO4-, 1.32 x 10(-6) M for Ca2+, 1.28 x 10(-6) M for Mg2+, 1.33 x 10(-) (6) M for Al3+, 1.31 x10(-6) M for Cl- and 1.24 x 10(-6) M for NO3-. The method was successfullyapplied to analysis of mineral water and composite tablets.