Catalogo Articoli (Spogli Riviste)

OPAC HELP

Titolo:
Angiographic and clinical one-year follow-up of the Cordis tantalum coil stent in a multicenter international study demonstrating improved restenosisrates when compared to pooled PTCA and BENESTENT-I data: The European Antiplatelet Stent Investigation (EASI)
Autore:
Rothman, MT; Serruys, PW; Grollier, G; Hoorntje, JCA; van den Bos, AA; Wijns, W; Gershlick, AH; Van Es, GA; Melkert, R; Eijgelshoven, MHJ; Lenderink, TT; Richardson, G; Dille-Amo, C;
Indirizzi:
London Chest Hosp, Dept Cardiol, London E2 9JX, England London Chest HospLondon England E2 9JX Cardiol, London E2 9JX, England Univ Hosp Rotterdam Dijkzigt, Ctr Thorax, Rotterdam, Netherlands Univ HospRotterdam Dijkzigt Rotterdam Netherlands tterdam, Netherlands CHU Cote Nacre, Caen, France CHU Cote Nacre Caen FranceCHU Cote Nacre, Caen, France Thorax Ctr Ignatius, Breda, Netherlands Thorax Ctr Ignatius Breda Netherlands Ctr Ignatius, Breda, Netherlands Glenfield Gen Hosp, Leicester LE3 9QP, Leics, England Glenfield Gen Hosp Leicester Leics England LE3 9QP E3 9QP, Leics, England
Titolo Testata:
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS
fascicolo: 2, volume: 52, anno: 2001,
pagine: 249 - 259
SICI:
1522-1946(200102)52:2<249:AACOFO>2.0.ZU;2-6
Fonte:
ISI
Lingua:
ENG
Soggetto:
CORONARY ANGIOPLASTY; WIKTOR STENT; QUANTITATIVE ANGIOGRAPHY; BALLOON ANGIOPLASTY; BYPASS GRAFTS; IMPLANTATION; TICLOPIDINE; COMPLICATIONS; EXPERIENCE; ASPIRIN;
Keywords:
stent; coronary intervention; PTCA;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Citazioni:
31
Recensione:
Indirizzi per estratti:
Indirizzo: Rothman, MT London Chest Hosp, Dept Cardiol, Bonner Rd, London E2 9JX, England London Chest Hosp Bonner Rd London England E2 9JX JX, England
Citazione:
M.T. Rothman et al., "Angiographic and clinical one-year follow-up of the Cordis tantalum coil stent in a multicenter international study demonstrating improved restenosisrates when compared to pooled PTCA and BENESTENT-I data: The European Antiplatelet Stent Investigation (EASI)", CATHET C IN, 52(2), 2001, pp. 249-259

Abstract

The Cordis tantalum coil stent was assessed in a nonrandomized multicentertrial: 275 patients with stable or unstable angina were entered. Clinical follow-up was for 1 year, with repeat angiography at 6 months. The major adverse cardiac event rates (MACE) were 3%, 14%, and 17% at 1, 7, and 13 months, respectively. The procedural success rate was 96% and the subacute occlusion rate 1.5%, in a group of patients over 60% of whom had ACC/AHA type B2 or C lesions. The binary restenosis rate at 6 months was 17.3%. Minimum lumen diameter increased from 1.07 +/- 0.28 mm preprocedure to 2.93 +/- 0.34mm poststenting and at 6 months was 1.99 +/- 0.69 mm. These results demonstrate that the Cordis tantalum stent can be used to treat complex lesions with good procedural success and tow rates of subacute thrombosis and restenosis at 6 months. Cathet Cardiovasc Intervent 2001;52:249-259. (C) 2001 Wiley-Liss, Inc.

ASDD Area Sistemi Dipartimentali e Documentali, Università di Bologna, Catalogo delle riviste ed altri periodici
Documento generato il 26/01/20 alle ore 23:10:43