Catalogo Articoli (Spogli Riviste)

OPAC HELP

Titolo:
Complications of femoral artery closure devices
Autore:
Carey, D; Martin, JR; Moore, CA; Valentine, M; Nygaard, TW;
Indirizzi:
Lynchburg Gen Hosp, Stroobants heart Ctr, Cardiac Catheterizat Lab, Lynchburg, VA 24501 USA Lynchburg Gen Hosp Lynchburg VA USA 24501 at Lab, Lynchburg, VA 24501 USA
Titolo Testata:
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS
fascicolo: 1, volume: 52, anno: 2001,
pagine: 3 - 7
SICI:
1522-1946(200101)52:1<3:COFACD>2.0.ZU;2-O
Fonte:
ISI
Lingua:
ENG
Soggetto:
TRANSLUMINAL CORONARY ANGIOPLASTY; CONVENTIONAL MANUAL COMPRESSION; CARDIAC-CATHETERIZATION; RANDOMIZED TRIAL; VASCULAR COMPLICATIONS; HEMOSTASIS DEVICE; COLLAGEN PLUG; INTERVENTION; ANGIOGRAPHY; MULTICENTER;
Keywords:
cardiac catheterization; coronary intervention; femoral artery complications; femoral artery closure device complications;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Citazioni:
21
Recensione:
Indirizzi per estratti:
Indirizzo: Nygaard, TW Lynchburg Gen Hosp, Stroobants heart Ctr, Cardiac CatheterizatLab, 1901 Tate Springs Rd, Lynchburg, VA 24501 USA Lynchburg Gen Hosp 1901Tate Springs Rd Lynchburg VA USA 24501
Citazione:
D. Carey et al., "Complications of femoral artery closure devices", CATHET C IN, 52(1), 2001, pp. 3-7

Abstract

We have examined our prospectively collected experience with femoral artery closure devices. Vasoseal (n = 937), Angioseal (N-742), and Techstar (n =1001) were utilized consecutively in our laboratory for diagnostic and interventional femoral artery closures. Complications were compared to a similar number of closures with manual compression (MC; n = 1019) before closuredevices were utilized. The incidence of surgical repair, acute femoral closure, transfusion due to groin complications, readmission for groin complications, infection, and total complications were examined. We found that theVasoseal and Angioseal devices were associated with higher rates of total complications than manual compression. The Techstar and manual compression had similar total complication rates. Acute femoral artery occlusion was a potentially serious complication with the Angioseal device. Groin infectionoccurred with each of the closure devices but not with manual compression. Cathet Cardiovasc Intervent 2001;52:3-7. (C) 2001 Wiley-Liss, Inc.

ASDD Area Sistemi Dipartimentali e Documentali, Università di Bologna, Catalogo delle riviste ed altri periodici
Documento generato il 25/02/20 alle ore 06:50:41