Efficacy of single lead VDD pacing in patients with impaired and normal left ventricular function
Autore:
Schuchert, A; Jakob, M; Treese, N; Scopfel, A; Schmidt, W; Jung, W; Kreuzer, J; Staedt, U; Stertmann, WA; Meinertz, T;
Indirizzi:
Univ Hamburg, Hosp Eppendorf, Dept Cardiol, Med Clin, D-20246 Hamburg, Germany Univ Hamburg Hamburg Germany D-20246 Med Clin, D-20246 Hamburg, Germany Knappschaftshosp Sulzbach, Sulzbach, Germany Knappschaftshosp Sulzbach Sulzbach Germany Sulzbach, Sulzbach, Germany Marien Hosp Osnabruck, Osnabruck, Germany Marien Hosp Osnabruck Osnabruck Germany p Osnabruck, Osnabruck, Germany Dist Hosp Kitzingen, Kitzingen, Germany Dist Hosp Kitzingen Kitzingen Germany osp Kitzingen, Kitzingen, Germany City Hosp Kassel, Kassel, Germany City Hosp Kassel Kassel GermanyCity Hosp Kassel, Kassel, Germany Univ Bonn, D-5300 Bonn, Germany Univ Bonn Bonn Germany D-5300Univ Bonn, D-5300 Bonn, Germany Bethanien, Frankfurt, Germany Bethanien Frankfurt GermanyBethanien, Frankfurt, Germany City Hosp Mannheim, Mannheim, Germany City Hosp Mannheim Mannheim Germany ty Hosp Mannheim, Mannheim, Germany Univ Hosp Giessen, Giessen, Germany Univ Hosp Giessen Giessen GermanyUniv Hosp Giessen, Giessen, Germany
Titolo Testata:
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY
fascicolo: 8, volume: 23, anno: 2000,
pagine: 1263 - 1267
SICI:
0147-8389(200008)23:8<1263:EOSLVP>2.0.ZU;2-3
Fonte:
ISI
Lingua:
ENG
Soggetto:
LONG-TERM; ATRIOVENTRICULAR-BLOCK; SURVIVAL; MODE; PACEMAKER; SYSTEMS;
Keywords:
single lead VDD pacing; VDD pacemaker; left ventricular function; advanced AV block; P wave amplitude;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Life Sciences
Citazioni:
21
Recensione:
Indirizzi per estratti:
Indirizzo: Schuchert, A Univ Hamburg, Hosp Eppendorf, Dept Cardiol, Med Clin, Martinistr 52, D-20246 Hamburg, Germany Univ Hamburg Martinistr 52 Hamburg Germany D-20246 , Germany
Citazione:
A. Schuchert et al., "Efficacy of single lead VDD pacing in patients with impaired and normal left ventricular function", PACE, 23(8), 2000, pp. 1263-1267

Abstract

Atrial synchronous ventricular pacing seems to be the best pacing mode forpatients with advanced AV block and impaired LV function. The long-term follow-up of single lead VDD pacing was studied in 33 patients with impaired LV function and compared to 42 patients with normal LV function. All patients received the same VDD lead and VDDR pacemaker. The lead model with 13-cmAV spacing between the atrial and ventricular electrode was implanted in 89% of the patients. Follow-ups were 1, 3, 6, and 12 months after implantation. The percentage of atrial sensing and the P wave amplitude were determined at each follow-up, Minimal P wave amplitude at implantation was 2.0 +/- 2.4 mV in patients with impaired and 1.7 +/- 0.9 mV with normal LV function(not significant). At the 12-month follow-up, 33 patients with normal and 23 patients with depressed LV function remained paced in the VDD mode. The remaining patients died in five (impaired LV function) and seven cases (normal LV function) or their pacemakers were programmed to the VVI/VVIR pacingmode in four (impaired LV function) and three cases (normal LV function). P wave amplitude did not differ in the two groups (e.g., at month 12: impaired: 1.17 +/- 9.42 mV: normal: 1.09 +/- 0.49 mV). The atrial sensitivity was programmed in most patients to sensitive settings with no differences between the two groups (e.g., at month 12: impaired: 0.13 +/- 0.06 mV; normal:0.13 +/- 0.05 mV), The diagnostic counters indicated nearly permanent atrial sensing (e.g., at month 22: impaired: 99.3 +/- 2.2%; normal: 94.0 +/- 1.0 mV). In conclusions, single lead VDD pacing restored AV synchronous ventricular pacing in patients with normal and with impaired LV function indicating that it could be an alternative to DDD pacemakers, but not to dual-chamber pacing.