Transfer of patients receiving advanced mechanical circulatory support
Autore:
McBride, LR; Lowdermilk, GA; Fiore, AC; Moroney, DA; Brannan, JA; Swartz, MT;
Indirizzi:
St Louis Univ, Hlth Sci Ctr, Dept Surg, Div Cardiothorac Surg, St Louis, MO 63110 USA St Louis Univ St Louis MO USA 63110 iothorac Surg, St Louis, MO 63110 USA
Titolo Testata:
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY
fascicolo: 5, volume: 119, anno: 2000,
pagine: 1015 - 1020
SICI:
0022-5223(200005)119:5<1015:TOPRAM>2.0.ZU;2-3
Fonte:
ISI
Lingua:
ENG
Soggetto:
POSTCARDIOTOMY CARDIOGENIC-SHOCK; VENTRICULAR ASSIST DEVICE; TRANSPORT;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Life Sciences
Citazioni:
12
Recensione:
Indirizzi per estratti:
Indirizzo: McBride, LR St Louis Univ, Hlth Sci Ctr, Dept Surg, Div Cardiothorac Surg,POB 15250,3635 Vista Ave & Grand Blvd, St Louis, MO 63110 USA St Louis Univ POB 15250,3635 Vista Ave & Grand Blvd St Louis MO USA 63110
Citazione:
L.R. McBride et al., "Transfer of patients receiving advanced mechanical circulatory support", J THOR SURG, 119(5), 2000, pp. 1015-1020

Abstract

Objective: Improving results with ventricular assist devices have led to their wider clinical application. Centers can stabilize, support, and wean or transfer patients to regional transplant centers,Methods: Prospectively collected data were reviewed to evaluate the clinical results of patients transferred to our institution while receiving advanced mechanical circulatory support. Results: Since 1993, 16 patients were accepted while receiving support with either extracorporeal membrane oxygenation or a ventricular assist device. The 10 male and 6 female patients ranged in age from 9 to 60 years (mean,42.1 years). Thirteen had had cardiac surgical procedures, two had acute myocardial infarctions, and one had myocarditis. The distance transported ranged from 0.2 to 309 miles (mean, 132 miles). Twelve patients were transferred by ground, and 4 were transported by air. Seven patients were originally supported with extracorporeal membrane oxygenation, 6 with centrifugal pumps, and 3 with ABIOMED ventricular assist devices (ABIOMED, inc, Danvers, Mass). Two patients had clinical complications during transfer, and one hada cerebrovascular accident, recovered, was weaned, and survived. A second patient had hemodynamic deterioration. There were no technical complications associated with transport. Six patients were left on the original supportdevice; 3 of the 6 were weaned and survived, and 3 died during support. The 10 remaining patients were switched to other ventricular assist devices: 9 patients to Thoratec devices (Thoratec Laboratories, Pleasanton, Calif) and 1 patient to a Novacor device (Baxter Healthcare Corp, Novacor Division,Oakland, Calif). Six of the 10 patients underwent transplantation and survived. Four patients died while being supported by the devices. Nine patients were discharged, with 1 late death at 29 months. Eight patients are alive3 to 65 months after discharge. Conclusions: These data suggest that patients receiving advanced support can be moved between clinical centers with acceptable risks. Because 33% of the survivors were weaned, transplantation is not required for survival.