3D reconstruction method from biplanar radiography using non-stereocorresponding points and elastic deformable meshes
Autore:
Mitton, D; Landry, C; Veron, S; Skalli, W; Lavaste, F; De Guise, JA;
Indirizzi:
ENSAM, Lab Biomecan, Paris, France ENSAM Paris FranceENSAM, Lab Biomecan, Paris, France Hop St Justine, Ctr Rech, Lab Informat Scoliose 3D, Montreal, PQ H3T 1C5, Canada Hop St Justine Montreal PQ Canada H3T 1C5 D, Montreal, PQ H3T 1C5, Canada Ecole Technol Super, Montreal, PQ, Canada Ecole Technol Super Montreal PQCanada chnol Super, Montreal, PQ, Canada Ecole Polytech, Montreal, PQ H3C 3A7, Canada Ecole Polytech Montreal PQ Canada H3C 3A7 h, Montreal, PQ H3C 3A7, Canada Hop Notre Dame de Bon Secours, Ctr Rech, Lab Rech Imagerie & Orthoped, Montreal, PQ H2L 4K8, Canada Hop Notre Dame de Bon Secours Montreal PQ CanadaH2L 4K8 H2L 4K8, Canada
Titolo Testata:
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING
fascicolo: 2, volume: 38, anno: 2000,
pagine: 133 - 139
SICI:
0140-0118(200003)38:2<133:3RMFBR>2.0.ZU;2-J
Fonte:
ISI
Lingua:
ENG
Soggetto:
MEDICAL IMAGE-ANALYSIS; HUMAN SPINE; 3-DIMENSIONAL RECONSTRUCTION; MODELS; VERTEBRAE; ANATOMY;
Keywords:
3D reconstruction; stereoradiography; non-stereocorresponding point; cervical spine; elastic deformable mesh;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Life Sciences
Engineering, Computing & Technology
Citazioni:
26
Recensione:
Indirizzi per estratti:
Indirizzo: Mitton, D ENSAM, Lab Biomecan, Paris, France ENSAM Paris FranceENSAM, Lab Biomecan, Paris, France
Citazione:
D. Mitton et al., "3D reconstruction method from biplanar radiography using non-stereocorresponding points and elastic deformable meshes", MED BIO E C, 38(2), 2000, pp. 133-139

Abstract

Standard 3D reconstruction of bones using stereoradiography is limited by the number of anatomical landmarks visible in more than one projection. Theproposed technique enables the 3D reconstruction of additional landmarks that can be identified in only one of the radiographs. The principle of thismethod is the deformation of an elastic object that respects stereocorresponding and non-stereocorresponding observations available in different projections. This technique is based on the principle that any non-stereocorresponding point belongs to a line joining the X-ray source and the projectionof the point in one view. The aim is to determine the 3D position of thesepoints on their line of projection when submitted to geometrical and topological constraints. This technique is used to obtain the 3D geometry of 18 cadaveric upper cervical vertebrae. The reconstructed geometry obtained is compared with direct measurements using a magnetic digitiser. The order of precision determined with the point-to-surface distance between the reconstruction obtained with that technique and reference measurements is about 1 mm, depending on the vertebrae studied. Comparison results indicate that the obtained reconstruction is close to the actual vertebral geometry. This method can therefore be proposed to obtain the 3D geometry of vertebrae.