Catalogo Articoli (Spogli Riviste)

OPAC HELP

Titolo:
Cardiac function in dialysis patients evaluated by Doppler echocardiography and its relation to intradialytic hypotension: A new index combining systolic and diastolic function
Autore:
Furukawa, K; Ikeda, S; Naito, T; Miyahara, Y; Iwasaki, T; Matsushita, T; Yakabe, E; Yamaguchi, K; Shikuwa, M; Muraya, Y; Kohno, S;
Indirizzi:
Nagasaki Univ, Sch Med, Dept Internal Med 2, Nagasaki, Japan Nagasaki Univ Nagasaki Japan Med, Dept Internal Med 2, Nagasaki, Japan Isahaya Gen Hosp, Nagasaki, Japan Isahaya Gen Hosp Nagasaki JapanIsahaya Gen Hosp, Nagasaki, Japan
Titolo Testata:
CLINICAL NEPHROLOGY
fascicolo: 1, volume: 53, anno: 2000,
pagine: 18 - 24
SICI:
0301-0430(200001)53:1<18:CFIDPE>2.0.ZU;2-D
Fonte:
ISI
Lingua:
ENG
Soggetto:
LEFT-VENTRICULAR FUNCTION; CHRONIC-RENAL-FAILURE; UREMIC CARDIOMYOPATHY; MYOCARDIAL PERFORMANCE; HEMODIALYSIS-PATIENTS; PARATHYROID-HORMONE; HYPERTROPHY; ANGIOGRAPHY; DISEASE;
Keywords:
hemodialysis; intradialytic hypotension; cardiac function; new Doppler index;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Life Sciences
Citazioni:
37
Recensione:
Indirizzi per estratti:
Indirizzo: Miyahara, Y Nagasaki Univ, Sch Med, Dept Internal Med 2, 1-7-1 Sakamoto, Nagasaki, Japan Nagasaki Univ 1-7-1 Sakamoto Nagasaki Japan Nagasaki, Japan
Citazione:
K. Furukawa et al., "Cardiac function in dialysis patients evaluated by Doppler echocardiography and its relation to intradialytic hypotension: A new index combining systolic and diastolic function", CLIN NEPHR, 53(1), 2000, pp. 18-24

Abstract

Aim. patients and methods: Cardiac function of 40 patients on maintenance dialysis was examined using a new Doppler index combining systolic and diastolic function. Immediately before dialysis, ultrasonic pulsed Doppler was used to measure right and left ventricular inflow and outflow waveforms. The sum of the isovolumetric contraction time (ICT) and isovolumetric relaxation time (IRT) was calculated by subtracting the ejection time from the interval between the end of an inflow waveform and the start of the next inflow waveform. The new index was obtained by dividing the sum of the two isovolumetric times by the ejection time. Cardiac function was evaluated in dialysis patients and healthy controls using new indices of the right and left heart systems. Results: Indices of the right and left heart systems in dialysis patients were significantly higher than those in healthy controls. With respect to hypotension during dialysis, patients were divided into two groups, a group with decreased blood pressure (group A: 27 patients) and a group with normal blood pressure (group B: 13 patients). Only the left heart system index in group A was significantly higher. There were no significantdifferences in other M-mode Doppler indices between the two groups. Conclusion: The new index was a more sensitive evaluator of cardiac function and predictor of hypotension during dialysis compared to standard echocardiographic indices.