Magnetic resonance cholangiopancreatography: Comparison between respiratory-triggered turbo spin echo and breath hold single-shot turbo spin echo sequences
Autore:
Papanikolaou, N; Karantanas, AH; Heracleous, E; Costa, JC; Gourtsoyiannis, N;
Indirizzi:
Philips Greece Med Syst, Athens 15561, Greece Philips Greece Med Syst Athens Greece 15561 d Syst, Athens 15561, Greece
Titolo Testata:
MAGNETIC RESONANCE IMAGING
fascicolo: 9, volume: 17, anno: 1999,
pagine: 1255 - 1260
SICI:
0730-725X(199911)17:9<1255:MRCCBR>2.0.ZU;2-5
Fonte:
ISI
Lingua:
ENG
Soggetto:
ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY; MR-CHOLANGIOPANCREATOGRAPHY; CHOLANGIOGRAPHY; ACQUISITION; CHOLEDOCHOLITHIASIS; DISEASES; DUCT;
Keywords:
bile ducts; cholangiography; turbo spin echo; comparative study;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Citazioni:
17
Recensione:
Indirizzi per estratti:
Indirizzo: Karantanas, AH Larissa Gen Hosp, Dept CT MRI, 1 Tsakalof Str, Larissa 41221, Greece Larissa Gen Hosp 1 Tsakalof Str Larissa Greece 41221 reece
Citazione:
N. Papanikolaou et al., "Magnetic resonance cholangiopancreatography: Comparison between respiratory-triggered turbo spin echo and breath hold single-shot turbo spin echo sequences", MAGN RES IM, 17(9), 1999, pp. 1255-1260

Abstract

The purpose of this study was to compare the relative conspicuity of the pancreaticobiliary tree on respiratory-triggered three-dimensional turbo spin echo (3D TSE RT) and breath hold single-shot turbo spin echo (SSTSE BH) acquisitions respectively in MRCP imaging. Both techniques were applied to 61 patients with clinically suspected pancreaticobiliary disease using a 1.0T MR system. All images were reviewed blindly, Qualitative comparison was made by grading subjectively the conspicuity of extrahepatic, intrahepatic,and main pancreatic ducts. Quantitative comparison included calculations of signal-to-noise ratio of the common bile duct, main pancreatic duct, gallbladder, liver, and contrast-to-noise ratio, relative contrast between common bile duct, gallbladder, and liver. 3D TSE RT provided significantly higher signal-to-noise ratio of the common bile duct (mean value 163.19) and main pancreatic duct (mean value 95.37) compared to SSTSE BH (mean values 76.24 and 26.22, respectively). 3D TSE RT was inferior to SSTSE BH for the depiction of intrahepatic ducts and pancreatic duct (head portion). 3D TSE RT and SSTSE BH sequences provide complimentary information in the visualization of the biliary and pancreatic ducts. Further comparative clinical studies are needed to redefine the sensitivity, specificity, and accuracy of MRCPusing both sequences. (C) 1999 Elsevier Science Inc.