Catalogo Articoli (Spogli Riviste)

OPAC HELP

Titolo:
A comparison of a new transtelephonic portable spirometer with a laboratory spirometer
Autore:
Izbicki, G; Abboud, S; Jordan, P; Perruchoud, AP; Bolliger, CT;
Indirizzi:
Univ Basel Hosp, Dept Internal Med, Div Pulm, Basel, Switzerland Univ Basel Hosp Basel Switzerland nal Med, Div Pulm, Basel, Switzerland Tel Aviv Univ, Dept Biomed Engn, IL-69978 Tel Aviv, Israel Tel Aviv Univ Tel Aviv Israel IL-69978 d Engn, IL-69978 Tel Aviv, Israel
Titolo Testata:
EUROPEAN RESPIRATORY JOURNAL
fascicolo: 1, volume: 14, anno: 1999,
pagine: 209 - 213
SICI:
0903-1936(199907)14:1<209:ACOANT>2.0.ZU;2-L
Fonte:
ISI
Lingua:
ENG
Soggetto:
PEAK EXPIRATORY FLOW; SELF-MANAGEMENT PLANS; LUNG TRANSPLANTATION; EDUCATION-PROGRAM; HOME SPIROMETRY; ASTHMA; REJECTION; ACCURACY; RATES; PEF;
Keywords:
asthma; flow-volume curve; home-monitoring; spirophone; telemedicine;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Life Sciences
Citazioni:
29
Recensione:
Indirizzi per estratti:
Indirizzo: Bolliger, CT Univ Stellenbosch, Fac Med, Dept Internal Med, ZA-7505 Tygerberg, South Africa Univ Stellenbosch Tygerberg South Africa ZA-7505 uth Africa
Citazione:
G. Izbicki et al., "A comparison of a new transtelephonic portable spirometer with a laboratory spirometer", EUR RESP J, 14(1), 1999, pp. 209-213

Abstract

The Spirophone is a new, portable transtelephonic spirometer which recordsthe slow and the forced expiratory vital capacity tests. Data can be transmitted via the telephone to a remote receiving centre, where a volume-time curve and the flow-volume curve are displayed on screen in real time. The aim of this study was to compare the newly developed transtelephonic spirometer, with a laboratory spirometer according to the American Thoracic Society (ATS) testing guidelines. Spirometry indices (slow vital capacity (SVC), forced vital capacity (FVC), forced expiratory volume in one second (FEV1), peak expiratory flow (PEF), forced expiratory flow at 25, 50 and 75% of FVC (FEF25, FEF50, and FEF75,respectively)) were measured from the SVC and the FVC tests in 45 subjects(30 patients, 15 healthy volunteers) according to the ATS standards. The data obtained with the laboratory system were compared to those from the Spirophone. The Spirophone measurements of SVC, FVC, FEV1, PEF, FEF25, FEF50 and FEF75correlated closely (r=0.91-0.98) to those from the laboratory system, whereas FEF25, FEF50, and FEF75 were significantly higher with the Spirophone. It is concluded that the Spirophone is comparable to the standard spirometry for home monitoring of slow vital capacity, forced vital capacity, forced expiratory volume in one second and peak expiratory flow. The validity ofthe manoeuvre can be assessed on screen in real time.

ASDD Area Sistemi Dipartimentali e Documentali, Università di Bologna, Catalogo delle riviste ed altri periodici
Documento generato il 04/12/20 alle ore 16:21:56