A one tenth scaled magnetically shielded room of double cylindrical HTS combined with ferromagnetic metals
Autore:
Haseyama, S; Kojima, N; Shibuya, S; Nakane, H; Yoshizawa, S;
Indirizzi:
Dowa Min Co Ltd, Hachioji, Tokyo, Japan Dowa Min Co Ltd Hachioji Tokyo Japan Min Co Ltd, Hachioji, Tokyo, Japan Shimizu Corp, Minato Ku, Tokyo, Japan Shimizu Corp Tokyo JapanShimizu Corp, Minato Ku, Tokyo, Japan Kogakuin Univ, Dept Elect Engn, Shinjuku Ku, Tokyo, Japan Kogakuin Univ Tokyo Japan v, Dept Elect Engn, Shinjuku Ku, Tokyo, Japan Meisei Univ, Adv Mat R&D Ctr, Hino, Tokyo, Japan Meisei Univ Hino Tokyo Japan i Univ, Adv Mat R&D Ctr, Hino, Tokyo, Japan
Titolo Testata:
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY
fascicolo: 2, volume: 9, anno: 1999,
parte:, 3
pagine: 3700 - 3703
SICI:
1051-8223(199906)9:2<3700:AOTSMS>2.0.ZU;2-T
Fonte:
ISI
Lingua:
ENG
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Physical, Chemical & Earth Sciences
Citazioni:
5
Recensione:
Indirizzi per estratti:
Indirizzo: Haseyama, S Dowa Min Co Ltd, Tobuki Cyo, Hachioji, Tokyo, Japan Dowa Min Co Ltd Tobuki Cyo Hachioji Tokyo Japan Tokyo, Japan
Citazione:
S. Haseyama et al., "A one tenth scaled magnetically shielded room of double cylindrical HTS combined with ferromagnetic metals", IEEE APPL S, 9(2), 1999, pp. 3700-3703

Abstract

This paper deals with a cylinder with both ends closed and a hole at the middle point on the side of both cylinders. The holes can be aligned to permit the examinee to enter or exit the double cylindrical MSR(Magnetically Shielded Room). An MSR one tenth the size of a human body was made. The diameter and length of the cylinder were 250mm and 350mm, respectively. The sizeof the hole was 90mmx180mm. The material used for this MSR was mainly highT-c superconductor with a coating of Bi2Sr2Ca1Cu2Ox 100 mu m thick. The ends of the MSR were plated with permalloy. To detect the inner magnetic fields at various points of the MSR, 33 sensors with three-dimensional sensitivity were placed at one closed end. The ratio of the internal to external field strength was measured by applying external magnetic fields parallel andperpendicular to the door. The readings of the ratios obtained were 10(-2)to 10(-3) in the parallel. and 10(-3) to 10(-4) in the perpendicular case.