Catalogo Articoli (Spogli Riviste)

OPAC HELP

Titolo:
Testing results of a second stage concentrator designed for the solar furnace of plataforma solar de Almeria
Autore:
Mendes, JF; Collares-Pereira, M; Martinez, D; Rodriguez, J; Padilla, DA;
Indirizzi:
INETI, DER ITE, P-1699 Lisbon, Portugal INETI Lisbon Portugal P-1699INETI, DER ITE, P-1699 Lisbon, Portugal Platforma Solar Almeria, Tabernas 04200, Almeria, Spain Platforma Solar Almeria Tabernas Almeria Spain 04200 4200, Almeria, Spain
Titolo Testata:
JOURNAL DE PHYSIQUE IV
fascicolo: P3, volume: 9, anno: 1999,
pagine: 569 - 574
SICI:
1155-4339(199903)9:P3<569:TROASS>2.0.ZU;2-1
Fonte:
ISI
Lingua:
ENG
Soggetto:
2-STAGE;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Physical, Chemical & Earth Sciences
Citazioni:
6
Recensione:
Indirizzi per estratti:
Indirizzo: Mendes, JF INETI, DER ITE, Estrada Paco do Lumiar, P-1699 Lisbon, PortugalINETI Estrada Paco do Lumiar Lisbon Portugal P-1699 , Portugal
Citazione:
J.F. Mendes et al., "Testing results of a second stage concentrator designed for the solar furnace of plataforma solar de Almeria", J PHYS IV, 9(P3), 1999, pp. 569-574

Abstract

On this work we present the main test results of a second stage concentrator (SSC) of the TERC type "Tailored Edge-Ray Concentrator", coupled to the actual parabolic primary of the solar furnace of the Plataforma Solar de Almeria, designed to improve the final concentration and temperature. Different options were considered for the SSC, but the primary geometry lead us tochoose the TERC one, because it comes closer to the thermodynamic limit and because it is more easy to construct and to use. The TERC design was modified to adequate it to the final use and was severely truncated to permit its placement inside of a vacuum chamber. This last constraint lowered the Gnat concentration and efficiency that we could expect. Anyway the test results show a substantial improvement on the solar furnace performance, which final concentration increased 1.4 times and which average flux density increased up to 3000kW/m(2) on the TERC exit.

ASDD Area Sistemi Dipartimentali e Documentali, Università di Bologna, Catalogo delle riviste ed altri periodici