Estimation of the effective dose applied by routine investigation of the chest, heart and abdomen with conventional CT, electron beam tomography and coronary angiography.
Autore:
Becker, C; Schatzl, M; Feist, H; Bauml, A; Schopf, UJ; Michalski, G; Lechel, U; Hengge, M; Bruning, R; Reiser, M;
Indirizzi:
Univrmanych, Klinikum Grosshadern, Inst Radiol Diagnost, D-81377 Munich, Ge Univ Munich Munich Germany D-81377 t Radiol Diagnost, D-81377 Munich, Ge Univ81377ch, Klinikum Grosshadern, Radiol Kliniken & Inst, Abt Med Phys, D- Univ Munich Munich Germany D-81377 iol Kliniken & Inst, Abt Med Phys, D- Inst Strahlenhyg, Bundesamt Strahlenschutz, Oberschleissheim, Germany InstStrahlenhyg Oberschleissheim Germany tz, Oberschleissheim, Germany Univ Munich, Klinikum Grosshadern, Med Klin 1, D-81377 Munich, Germany Univ Munich Munich Germany D-81377 , Med Klin 1, D-81377 Munich, Germany
Titolo Testata:
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN
fascicolo: 1, volume: 170, anno: 1999,
pagine: 99 - 104
SICI:
0936-6652(199901)170:1<99:EOTEDA>2.0.ZU;2-Q
Fonte:
ISI
Lingua:
GER
Soggetto:
SPIRAL COMPUTED-TOMOGRAPHY; RADIATION;
Keywords:
chest CT; abdomen CT; computed tomography (CT); radiation exposure; radiation measurements; electron beam computed tomography; cardiac angiography;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Clinical Medicine
Citazioni:
21
Recensione:
Indirizzi per estratti:
Indirizzo: Becker, C Univ Munich, Klinikum Grosshadern, Inst Radiol Diagnost, Marchioninistr 15, Univ Munich Marchioninistr 15 Munich Germany D-81377 inistr 15,
Citazione:
C. Becker et al., "Estimation of the effective dose applied by routine investigation of the chest, heart and abdomen with conventional CT, electron beam tomography and coronary angiography.", ROFO-F RONT, 170(1), 1999, pp. 99-104

Abstract

Purpose: To compare the effective dose applied by sequential CT (SEQ), spiral CT (SCT), electron beam CT (EBT) and coronary angiography for investigations of the chest, abdomen and the heart. Methods: The Alderson Phantom was used to compare the effective dose for all modalities. In addition, the effective dose for conventional CT (SEQ and SCT) was estimated with a mathematical phantom. Results: For CT investigation of the chest and abdomen the dose was highest for the EBT (11 mSv and 25 mSv, respectively) and slightlylower for the SEQ (7.8 mSv and 21.5 mSv, respectively), whereas spiral CT required the least dose (5,3 mSv and 8,8 mSv, respectively). For coronary calcium screening (0.8 mSv) and EBT coronary angiography (1.7 mSv) the dose was lower than for coronary catheter angiography (3.3 mSv). For conventional CT the difference between the effective dose derived by the mathematical phantom and by the Alderson phantom was 2% to 20%. Conclusions: For investigations of the chest and abdomen the effective dose applied by SCT is significantly lower than that with EBT and SEQ. For investigation of the coronary arteries the effective dose applied by EBT is lower than that for coronary catheter angiography.