Catalogo Articoli (Spogli Riviste)

OPAC HELP

Titolo:
FATIGUE FAILURE OF HOLD-DOWN BOLTS FOR A HYDRAULIC CYLINDER GLAND
Autore:
TAO C; XI N; YAN H; ZHANG Y;
Indirizzi:
AVIC FAILURE ANAL CTR,POB 81-4 BEIJING 100095 PEOPLES R CHINA
Titolo Testata:
Engineering failure analysis
fascicolo: 3, volume: 5, anno: 1998,
pagine: 241 - 246
SICI:
1350-6307(1998)5:3<241:FFOHBF>2.0.ZU;2-8
Fonte:
ISI
Lingua:
ENG
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Science Citation Index Expanded
Science Citation Index Expanded
Citazioni:
NO
Recensione:
Indirizzi per estratti:
Citazione:
C. Tao et al., "FATIGUE FAILURE OF HOLD-DOWN BOLTS FOR A HYDRAULIC CYLINDER GLAND", Engineering failure analysis, 5(3), 1998, pp. 241-246

Abstract

A hydraulic-cylinder gland system used in aircraft failed by leaking because the hold-down bolts broke in the course of a trial run. The metallographic examination of the fracture surface and the stress calculations for the bolts are described in this article. The investigation showed that the failure was caused by fatigue and the reason for failure was considered in relation to the processing, surface condition andassembly of the bolts. Measures to increase the fatigue strength of the bolts are proposed. (C) 1998 Elsevier Science Ltd. All rights reserved.

ASDD Area Sistemi Dipartimentali e Documentali, Università di Bologna, Catalogo delle riviste ed altri periodici
Documento generato il 28/11/20 alle ore 21:47:15