ROC EVALUATION OF SPECT MYOCARDIAL LESION DETECTABILITY WITH AND WITHOUT SINGLE ITERATION NONUNIFORM CHANG ATTENUATION COMPENSATION USING AN ANTHROPOMORPHIC FEMALE PHANTOM
Autore:
JANG SY; JASZCZAK RJ; TSUI BMW; METZ CE; GILLAND DR; TURKINGTON TG; COLEMAN RE;
Indirizzi:
UNIV PENN,MED CTR PHILADELPHIA PA 19104 DUKE UNIV,MED CTR DURHAM NC 27710 UNIV N CAROLINA CHAPEL HILL NC 27599 UNIV CHICAGO,MED CTR CHICAGO IL 60637
Titolo Testata:
IEEE transactions on nuclear science
fascicolo: 4, volume: 45, anno: 1998,
parte:, 2
pagine: 2080 - 2088
SICI:
0018-9499(1998)45:4<2080:REOSML>2.0.ZU;2-W
Fonte:
ISI
Lingua:
ENG
Soggetto:
IMAGING TECHNIQUES; BEAM COLLIMATION; TRANSMISSION CT; RECONSTRUCTION; MAPS;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Science Citation Index Expanded
Science Citation Index Expanded
Citazioni:
21
Recensione:
Indirizzi per estratti:
Citazione:
S.Y. Jang et al., "ROC EVALUATION OF SPECT MYOCARDIAL LESION DETECTABILITY WITH AND WITHOUT SINGLE ITERATION NONUNIFORM CHANG ATTENUATION COMPENSATION USING AN ANTHROPOMORPHIC FEMALE PHANTOM", IEEE transactions on nuclear science, 45(4), 1998, pp. 2080-2088

Abstract

The purpose of this work was to evaluate lesion detectability with and without nonuniform attenuation compensation (AC) in myocardial perfusion SPECT imaging in women using an anthropomorphic phantom and receiver operating characteristics (ROC) methodology. Breast attenuation causes artifacts in reconstructed images and may increase the difficultyof diagnosis of myocardial perfusion imaging in women. The null hypothesis tested using the ROC study was that nonuniform AC does not change the lesion detectability in myocardial perfusion SPECT imaging in women. We used a filtered backprojection (FBP) reconstruction algorithm and Chang's single iteration method for AC. In conclusion, with out proposed myocardial defect model nuclear medicine physicians demonstrated no significant difference for the detection of the anterior wall defect; however, a greater accuracy for the detection of the inferior wall defect was observed without nonuniform AC that with it (P- value = 0.0034). Medical physicists did not demonstrate any statistically significant difference in defect detection accuracy with or without nonuniform AC in the female phantom.