UNIFORMITY OF RESPONSE OF THE LHC1 LARGE-AREA PIXEL DETECTOR SYSTEM
Autore:
CANTATORE E; ANTINORI F; BECKS KH; BEKER H; BUIS EJ; BURGER P; CAMPBELL M; CASAGRANDE L; CATANESI MG; CHESI E; DAURIA S; DAVIA C; DIBARI D; DILIBERTO S; GYS T; HEIJNE EHM; HUMPSTON G; JACHOLKOWSKI A; JAEGER JJ; KLEMPT W; KUBASTA J; LEITNER R; LENTI V; LUPTAK M; MARTINENGO P; MAZZONI MA; MEDDELER G; MEDDI F; MIDDELKAMP P; MIKULEC B; MORANDO M; PELLEGRINI F; POSPISIL S; QUERCIGH E; RIDKY J; ROPOTAR I; SAFARIK K; SALADINO S; SCHARFETTER L; SEGATO G; SIMONE S; SMITH K; SNOEYS W; SOBCZYNSKI C; TOMASICCHIO G; VRBA V;
Indirizzi:
CERN MEYRIN,ECP DIV CH-1211 GENEVA 23 SWITZERLAND IST NAZL FIS NUCL I-70126 BARI ITALY POLITECN BARI BARI ITALY IST NAZL FIS NUCL PADUA ITALY UNIV PADUA I-35100 PADUA ITALY BERG UNIV GESAMTHSCH WUPPERTAL D-42097 WUPPERTAL GERMANY NIKHEF H NL-1009 DB AMSTERDAM NETHERLANDS CANBERRA SEMICOND NV CANBERRA ACT AUSTRALIA LIP P-1000 LISBON PORTUGAL UNIV BARI I-70121 BARI ITALY UNIV UDINE I-33100 UDINE ITALY INFN UDINE ITALY UNIV GLASGOW GLASGOW G12 8QQ LANARK SCOTLAND IST NAZL FIS NUCL ROME ITALY UNIV ROME ROME ITALY GEC MARCONI LTD TOWCESTER NORTHANTS ENGLAND COLL FRANCE F-75231 PARIS FRANCE GRP PRAHA PRAGUE CZECH REPUBLIC SLOVAK ACAD SCI,INST EXPT PHYS KOSICE 04353 SLOVAKIA UNIV WARSAW PL-00325 WARSAW POLAND
Titolo Testata:
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
fascicolo: 1-3, volume: 409, anno: 1998,
pagine: 119 - 128
SICI:
0168-9002(1998)409:1-3<119:UOROTL>2.0.ZU;2-S
Fonte:
ISI
Lingua:
ENG
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Science Citation Index Expanded
Science Citation Index Expanded
Science Citation Index Expanded
Science Citation Index Expanded
Citazioni:
5
Recensione:
Indirizzi per estratti:
Citazione:
E. Cantatore et al., "UNIFORMITY OF RESPONSE OF THE LHC1 LARGE-AREA PIXEL DETECTOR SYSTEM", Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 409(1-3), 1998, pp. 119-128

Abstract

The uniformity of discriminator threshold and the precision of internal delay have been studied on single 'Omega3/LHC1' pixel readout chipsand on arrays of 24 chips containing 48 768 active pixels. On single chips we measured a threshold variation of 400e(-) r.m.s, for a mean threshold setting of 4000e(-). The internal delay distribution shows a standard deviation of 6 ns on a single chip and 16 ns on the large arrays, after applying a 3-bit delay adjustment. These results, obtained using an electrical stimulus, were confirmed by tests in a beam of high-energy particles. (C) 1998 Elsevier Science B.V. All rights reserved.