Catalogo Articoli (Spogli Riviste)

OPAC HELP

Titolo:
COMPARISON OF LOW-TECHNOLOGY AND HIGH-TECHNOLOGY MONITORING OF CLOMIPHENE CITRATE OVULATION INDUCTION
Autore:
SMITH YR; RANDOLPH JF; CHRISTMAN GM; ANSBACHER R; HOWE DM; HURD WW;
Indirizzi:
UNIV MICHIGAN,MED CTR,WOMENS HOSP,DEPT OBSTET & GYNECOL,1500 E MED CTR DR,ROOM L4000 ANN ARBOR MI 48109 UNIV MICHIGAN,MED CTR,DEPT OBSTET & GYNECOL,DIV REPROD ENDOCRINOL ANNARBOR MI 48109
Titolo Testata:
Fertility and sterility
fascicolo: 1, volume: 70, anno: 1998,
pagine: 165 - 168
SICI:
0015-0282(1998)70:1<165:COLAHM>2.0.ZU;2-T
Fonte:
ISI
Lingua:
ENG
Soggetto:
LUTEINIZING-HORMONE; CYCLES;
Keywords:
ULTRASOUND; LH SURGE; MONITORING; CLOMIPHENE CITRATE;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Science Citation Index Expanded
Citazioni:
14
Recensione:
Indirizzi per estratti:
Citazione:
Y.R. Smith et al., "COMPARISON OF LOW-TECHNOLOGY AND HIGH-TECHNOLOGY MONITORING OF CLOMIPHENE CITRATE OVULATION INDUCTION", Fertility and sterility, 70(1), 1998, pp. 165-168

Abstract

Objective: To determine whether newer monitoring techniques, including urinary detection of the LH surge and vaginal ultrasound, offer an advantage over basal body temperature (BBT) charts alone in achieving pregnancy using clomiphene citrate (CC). Design: Randomized clinical trial. Setting: Infertility patients in an academic research environment. Patient(s): Forty-five women undergoing ovulation induction with CC. Intervention(s): The women were assigned randomly to receive either low- or high-technology ovulation monitoring for a total of 3 ovulatorycycles. Both groups were followed with BET charts. The high-technology group also was monitored with urinary LH kits and vaginal ultrasound. Main Outcome Measure(s): Cycle fecundity rates for each technique were compared statistically with use of life-table analysis. Result(s): Forty-five patients were studied during a total of 134 cycles. The overall cycle fecundity rate was 8%, 10% (8 of 81 cycles) for the low-technology monitoring group and 6% (3 of 53 cycles) for the high-technology monitoring group. These rates were not statistically significant when evaluated by Fisher's exact test (P = .53) or when using life-tableanalysis and a log-rank test (P = .48). Conclusion(s): These data suggest that for initial attempts at ovulation induction with CC in unselected patients, high-technology monitoring of ovulation offers no increase in fecundity over low-technology monitoring. (Fertil Steril(R) 1998;70:165-8. (C)1998 by American Society for Reproductive Medicine.).