Catalogo Articoli (Spogli Riviste)

OPAC HELP

Titolo:
CONFOCAL SCANNING LASER FLUORESCEIN AND I NDOCYANINE GREEN ANGIOGRAPHY
Autore:
HOLZ FG; BELLMANN C; DITHMAR S; ROHRSCHNEIDER K; BURK ROW; VOLCKER HE;
Indirizzi:
UNIV HEIDELBERG,AUGENKLIN,NEUENHEIMER FELD 400 D-69120 HEIDELBERG GERMANY
Titolo Testata:
Der Ophthalmologe
fascicolo: 5, volume: 94, anno: 1997,
pagine: 348 - 353
SICI:
0941-293X(1997)94:5<348:CSLFAI>2.0.ZU;2-1
Fonte:
ISI
Lingua:
GER
Soggetto:
CHOROIDAL NEOVASCULARIZATION; OPHTHALMOSCOPE; VIDEOANGIOGRAPHY; CIRCULATION;
Keywords:
SCANNING LASER OPHTHALMOSCOPY; FLUORESCEIN ANGIOGRAPHY; INDOCYANINE GREEN ANGIOGRAPHY; CHOROIDAL NEOVASCULARIZATION; AGE-RELATED MACULAR DEGENERATION;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Science Citation Index Expanded
Citazioni:
25
Recensione:
Indirizzi per estratti:
Citazione:
F.G. Holz et al., "CONFOCAL SCANNING LASER FLUORESCEIN AND I NDOCYANINE GREEN ANGIOGRAPHY", Der Ophthalmologe, 94(5), 1997, pp. 348-353

Abstract

Background: We report on our clinical experience with a recently developed confocal scanning laser ophthalmoscope for simultaneous fluorescein and indocyanine-green (ICG) angiography. Materials and methods: Following injection of fluorescein and ICG mixed in one syringe simultaneous confocal scanning laser fluorescein and ICG angiography were carried out using the Heidelberg Retina Angiograph (HRA). An argon laser (488 nm) and a diode laser beam (795 nm) from an external source were delivered via single-mode fibers. Emission was recorded between 500 and650 nm and above 810 nm, respectively. Digital images were displayed simultaneously on a monitor during angiography. Results: A total of 295 simultaneous angiograms in 268 patients with various retinal and choroidal diseases, including exudative age-related macular degeneration with oc cult and classic choroidal neovascularization, were obtained. High-contrast images during all phases of the angiography were obtained. Besides mild side effects in similar frequency known from individual injections, no additional toxic or allergic reactions from simultaneous injections of the two dyes were observed. Conclusions: Confocal laser scanning angiography allows for simultaneous fluorescein and ICG angiography. Compared with consecutive investigations using both dyes, simultaneous angiography requires only one injection,and offers identical digital frames. Simultaneous injection is not associated with additional side effects.

ASDD Area Sistemi Dipartimentali e Documentali, Università di Bologna, Catalogo delle riviste ed altri periodici
Documento generato il 25/11/20 alle ore 18:34:46