Catalogo Articoli (Spogli Riviste)

OPAC HELP

Titolo:
MODELING THE SCATTER RESPONSE FUNCTION IN INHOMOGENEOUS SCATTERING MEDIA FOR SPECT
Autore:
FREY EC; TSUI BMW;
Indirizzi:
UNIV N CAROLINA,DEPT BIOMED ENGN CHAPEL HILL NC 27514 UNIV N CAROLINA,DEPT RADIOL CHAPEL HILL NC 27514
Titolo Testata:
IEEE transactions on nuclear science
fascicolo: 4, volume: 41, anno: 1994,
parte:, 1
pagine: 1585 - 1593
SICI:
0018-9499(1994)41:4<1585:MTSRFI>2.0.ZU;2-G
Fonte:
ISI
Lingua:
ENG
Soggetto:
EMISSION COMPUTED-TOMOGRAPHY; WINDOWED SUBTRACTION TECHNIQUES; MONTE-CARLO; COMPTON-SCATTER; PROJECTOR-BACKPROJECTOR; PRACTICAL METHOD; COMPENSATION; DECONVOLUTION; IMAGES; QUANTIFICATION;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Science Citation Index Expanded
Science Citation Index Expanded
Citazioni:
34
Recensione:
Indirizzi per estratti:
Citazione:
E.C. Frey e B.M.W. Tsui, "MODELING THE SCATTER RESPONSE FUNCTION IN INHOMOGENEOUS SCATTERING MEDIA FOR SPECT", IEEE transactions on nuclear science, 41(4), 1994, pp. 1585-1593

Abstract

We have previously developed a method for accurately and rapidly modeling the scatter response function in uniform media. In this work we studied the extension of this method to nonuniform attenuators. Our approach was to use the water-equivalent source depth, i.e., the integralof the attenuation coefficient through the nonuniform object from thesource to the surface divided by the attenuation coefficient of water. We have investigated the accuracy of three different methods based on this approximation using Monte Carlo (MC) simulation methods. Line sources were placed at the same water equivalent depth in slabs composed of water, bone, and lung. We observed that, for perfect collimation,the scatter response functions (SRFs) obtained for these slabs are comparable. To determine whether attenuation coefficients alone are sufficient to estimate the SRF or whether one must know the elemental composition, we simulated SRFs for sources in bone and lungs as well as bone- and lung-equivalent materials. The bone- and lung-equivalent materials have the same attenuation coefficient as bone and lung, respectively, but the same elemental composition as water. For the lung-equivalent material, the SRFs were essentially equivalent to those from lung;for the bone-equivalent material, the SRFs were closer to those from water. We have also placed voids of various sizes in slab phantoms while keeping the same water-equivalent source depth. For these simple geometries two of the methods based on the effective depth were adequatefor predicting the SRF. Finally, we have simulated the SRF for a linesource in a realistic thorax phantom using several methods based on geometric and water-equivalent distances. The results indicate that oneof the methods gives reasonably good agreement with direct MC simulations in terms of predicting the magnitude and shape of the SRFs and projection data for a complex distribution simulating the heart. This method was not the same as the one that gave good agreement in the case of the simpler phantoms.

ASDD Area Sistemi Dipartimentali e Documentali, Università di Bologna, Catalogo delle riviste ed altri periodici
Documento generato il 27/01/20 alle ore 01:24:25