WAVELET ANALYSIS OF REAL EAR AND SYNTHESIZED CLICK-EVOKED OTOACOUSTICEMISSIONS
Autore:
WIT HP; VANDIJK P; AVAN P;
Indirizzi:
UNIV HOSP GRONINGEN,INST AUDIOL,POB 30001 9700 RB GRONINGEN NETHERLANDS FAC MED CLERMONT FERRAND,BIOPHYS LAB CLERMONT FERRAND FRANCE
Titolo Testata:
Hearing research
fascicolo: 2, volume: 73, anno: 1994,
pagine: 141 - 147
SICI:
0378-5955(1994)73:2<141:WAOREA>2.0.ZU;2-E
Fonte:
ISI
Lingua:
ENG
Keywords:
OTOACOUSTIC EMISSIONS; WAVELETS; LATENCY; TIME-FREQUENCY MAP;
Tipo documento:
Article
Natura:
Periodico
Settore Disciplinare:
Science Citation Index Expanded
Science Citation Index Expanded
Citazioni:
14
Recensione:
Indirizzi per estratti:
Citazione:
H.P. Wit et al., "WAVELET ANALYSIS OF REAL EAR AND SYNTHESIZED CLICK-EVOKED OTOACOUSTICEMISSIONS", Hearing research, 73(2), 1994, pp. 141-147

Abstract

Wavelet analysis was performed to obtain time-frequency analyses of click evoked otoacoustic emissions from normal ears and one ear with a high-frequency hearing loss; mainly to introduce this relatively new method and to show its potentials for emission analysis. The same analysis was then used to obtain time-frequency decompositions of synthesized emissions. It was found that the introduction of a slightly irregular frequency to place relation for the inner ear yielded synthetic results that were remarkably similar to those obtained from real ears.

ASDD Area Sistemi Dipartimentali e Documentali, Università di Bologna, Catalogo delle riviste ed altri periodici